John Deere HR-BG5002 Manual Do Utilizador

Página de 80
Operator’s Manual   
 
 
 
 
 
       
             
Symptom 
 
 
 
Problem   
 
 
 
Solution
Smell Gas. 
 
 
 
 
 
 
 
 
Shut-off lP-Gas Cylinder Valve  
    
 
 
 
 
 
 
 
 
 
at once. dO nOT use the  
    
 
 
 
 
 
 
 
 
 
appliance until leak is sealed. 
 
Leak detected at cylinder, regulator or  Regulator fitting loose.   
 
Tighten fitting and “Leak Test”.
other connections. 
 
 
    
 
 
 
 
Gas leak in hose/regulator or control 
See authorized service center.
    
 
 
 
 
valves.
Flame flashback beneath control panel.  Venturi blocked.  
 
 
Remove burner, clean ventrui.    
    
 
 
 
 
 
 
 
 
 
See “Venturi Tube”.
Burner will not light. 
 
 
Out of LP-Gas.   
 
 
Refill LP-Gas Cylinder.
    
 
 
 
 
Ignitor wire(s) not connected.   
Connect both main burner and    
    
 
 
 
 
 
 
 
 
 
side burner electrode wires.
    
 
 
 
 
Ignitor electrode misaligned on burner.  Realign electrodes.
    
 
 
 
 
Ignitor malfunction. 
 
 
Use “Manual Lighting” procedures.
    
 
 
 
 
Regulator is not fully connected to the   Tighten the regulator hand-wheel.
    
 
 
 
 
cylinder valve.   
 
    
 
 
 
 
Burner valve left open while cylinder  
Close burner and cylinder valves.
    
 
 
 
 
valve was opened causing excess  
Open cylinder valve slowly, then
    
 
 
 
 
flow device to activate.   
 
open burner valve to light.
    
 
 
 
 
A leak in the system causing the  
Leak test connections to  
    
 
 
 
 
excess flow device to activate.   
determine loose fitting. Tighten    
    
 
 
 
 
 
 
 
 
 
fitting. Leak test system.
    
 
 
 
 
Venturi blocked.  
 
 
Remove burner, clean venturi See  
    
 
 
 
 
 
 
 
 
 
“Venturi Tubes”.
    
 
 
 
 
Venturi not aligned with valve orifice. 
Realign venturi to orifice. See 
    
 
 
 
 
 
 
 
 
 
“Venturi Tubes”.
    
 
 
 
 
Orifice blocked.  
 
 
Remove burner, clean orifice with  
    
 
 
 
 
 
 
 
 
 
a pin or fine wire. Do not attempt  
    
 
 
 
 
 
 
 
 
 
to drill orifice.
    
 
 
 
 
Hose is twisted.  
 
 
Straighten hose. Keep away from  
    
 
 
 
 
 
 
 
 
 
bottom casting.
Decreasing heat, “popping sound”. 
Out of LP-Gas.   
 
 
Refill LP-Gas Cylinder.
  
    
 
 
 
 
Venturi blocked.  
 
 
Remove burner, clean venturi.    
    
 
 
 
 
 
 
 
 
 
See “Venturi Tubes”.
Hot spots on cooking surface.   
Venturi blocked.  
 
 
Remove burner, clean venturi.    
    
 
 
 
 
 
 
 
 
 
See “Venturi Tubes”
Troubleshooting