If your data capture results in something similar to what is
shown  here  in 
Figure  3
  or  in 
Figure  4
,  take  another
sample. It may take a few trials to get good data.
Figure  4    Marginal  data  capture  that  results  from  trying  to
capture  data  that  is  near  but  not  right  at  the  point  where  the
ADC outputs are in transition.
Figure 5. Normal data capture.
Coherent sampling of a periodic waveform occurs when a
prime  integer  number  of  cycles  exists  in  the  sample
window.  The  relationship  between  the  number  of  cycles
sampled  (CY),  the  number  of  samples  taken  (SS),  the
signal  input  frequency  (fin) and the sample rate (fs), for
coherent sampling, is
Figure 3.  Poor data capture resulting from trying to capture
data while the ADC outputs are in transition
6.2 Coherent Sampling
Artifacts  can  result  when  we  perform  an  FFT  on  a
digitized  waveform,  producing  inconsistent  results  when
testing repeatedly. The presence of these artifacts means
that  the  ADC  under  test  may  perform  better  than  the
measurements would indicate.
CY
SS
f
in
f
s
=
CY, the number of  cycles  in  the  data  record,  must  be  a
prime integer number and SS, the number of samples in
the data record, must be a factor of 2 integer.
We  can  eliminate  the  need  for  windowing  and  get  more
consistent results if we observe the proper ratios between
the input and sampling frequencies. We call this 
coherent
sampling
.  Coherent  sampling  greatly  increases  the
spectral  resolution  of  the  FFT,  allowing  us  to  more
accurately  evaluate  the  spectral  response  of  the  A/D
converter.  When  we  do  this,  however,  we  must  be  sure
that the input signal has high spectral purity and stability
and  that  the  sampling  clock  signal  is  extremely  stable
with minimal jitter.
Further, fin (signal input frequency) and fs (sampling rate)
should  be  locked  to  each  other  so  that  the  relationship
between  the  two  frequencies  is  exact.  Locking  the  two
signal  sources  to  each  other  also  causes
 
whatever
sample-to-sample clock edge timing  variation  (jitter)  that
is present in the two signals to cancel each other.
Windowing (an FFT Option under WaveVision) should be
turned off for coherent sampling.
7.0 Evaluation Board Specifications
Board Size:
6.5" x 3.5" (16.5 cm x 8.9 cm)
Power Requirements:
+5.0V, 100 mA (ADC12040 /
ADC12010 / ADC12020) or
+3.3V, 120 mA (ADC12L063)
+5V @ 30 mA / 1A (see Sect 4.6)
Clock Frequency Range:
1.0 MHz to 40 MHz or 60 MHz
Analog Input
Nominal Voltage:
1.4VP-P
Impedance:
50 Ohms
              
7
          