Matrox Electronic Systems II Manual Do Utilizador

Página de 136
62      Chapter 5: Matrox Meteor-II hardware reference
Trigger
Matrox Meteor-II /Multi-Channel accepts an external trigger 
input which allows image acquisition to be synchronized to 
external events. The board can operate in one of two modes, and 
the selected mode is specified by the DCF.
Matrox Meteor-II /Multi-Channel can operate in next valid 
frame/field mode When in this mode, the digitizer waits for the 
next valid frame or field (as specified by the DCF file) before 
commencing the grab. This trigger mode functions in one of 
three ways:
Edge-triggered monoshot acquisition: The VIA (Video 
Interface Asic) waits for the rising/falling* edge to capture a 
single frame.
Edge-triggered continuous acquisition: The VIA waits 
for the rising/falling* edge to start a continous grab.
Level-sensitive "continuous" acquisition: The VIA grabs 
continuously while the level of the trigger is high/low*.
* The polarity of the active and inactive levels of the trigger 
signal are software programmable.
Matrox Meteor-II /Multi-Channel can also operate in 
asynchronous reset mode. In this mode, the digitizer resets the 
camera to begin a new frame when the trigger signal is received. 
Direct TTL trigger
Trigger signals can be received in TTL format directly through 
the video-input connector on the PCI form factor. The TTL level 
signal must have a maximum amplitude of 5 V. A signal over 
2 V is considered high while anything less than 0.8 V is 
considered low. The transition of 0.8 V to 2 V is considered to 
be the rising edge.
The trigger signal’s pulse width must be greater than one pixel. 
You can determine the pulse width by taking the inverse of the 
pixel frequency. For example, if the pixel frequency is 
12.27 MHz, the minimum pulse width is 1/12.27 MHz 
 82 
nanoseconds.
Note the PC/104-Plus form factor does not support a TTL 
trigger.