NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
3
Installation must conform to local codes. 
In  the  absence  of  local  codes,  electrical 
wiring  and  grounding  must  comply  with 
the  National  Electrical  Code  ANSI/  NFPA 
70  -  latest  edition.    In  Canada,  the  cur-
rent CSA C22-1 Canadian Electrical Code 
- latest edition.
CONgRATULATIONS!
In selecting this LENNOX Merit Plus electric fireplace, you have chosen the finest and 
most dependable fireplace found anywhere.  A beautiful and prestigious addition to 
the finest homes.  Welcome to a Family of hundreds of thousands of satisfied LENNOX 
Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual.  Please 
pay special attention to the safety instructions provided in this manual.  The instruc-
tions included here will assure that you have many years of dependable and enjoyable 
service from your LENNOX product.
TAbLE OF CONTENTS
Important Safety Information ........... Page  2
Packaging List .................................. Page  3
Introduction ..................................... Page  3
General Information ......................... Page  3
Locating Fireplace ............................ Page  3
Tools/Supplies Required .................. Page  3
Framing Specifications ..................... Page  4
Fireplace Specifications .................... Page  4
Clearances ....................................... Page  5
Pre-installation ................................. Page  5
Installation Steps ............................. Page  5
Electrical Connections ...................... Page  5
Final Finishing .................................. Page  6
Break-In Period ................................ Page  6
Control Panel Operation ................... Page  6
Remote Control Operation ............... Page  7
Maintenance ..................................... Page  8
Wiring Diagrams .............................. Page  10
Troubleshooting ............................... Page  15
Replacement Parts ........................... Page  16
Optional Accessories ........................ Page  18
PACKAgINg LIST
This assembled Electric Room Heater is 
packaged with:
•   One  accessory  package  located  in  the 
firebox, containing; 
1. One Installation and Operation Manual.
2. One Warranty Certificate.
3. One Remote Control.
•   Two spare Light Bulbs are located in a 
recess on the back of the log assembly.
INTRODUCTION
This  Electric  Fireplace  is  designed  for 
residential  applications  to  be  framed  in 
as a fireplace.
This appliance has been tested in accor-
dance  with  UL  2021  and  CSA  C22.2  No. 
46-M198 standards for fixed and location 
dedicated electric room heaters.
       WARNINg 
Do not install or operate this fire-
place through a switch wired in the 
120 VAC or  240 VAC circuits.  The 
only approved wiring for a switch 
is through the low voltage circuit  
(24 VAC) as shown on Page 14.
gENERAL INFORMATION
Power Supply Wire Specifications
120 Volt, 60 Hz, 1600 Watts:
(ref. Page 10)
Hard  Wire  Connection  -  Use  two  conductor, 
non-metallic  sheath  cable  with  ground  wire 
(total  three  wires)  for  the  incoming  power 
supply.  The wire used must conform to local 
and national electrical codes for the specified 
power consumption rating. See Table 1.
240 Volt, 60 Hz, 3000 Watt:
(ref. Page 11)
Use three conductor, non-metallic sheath cable 
with  ground  wire  (total  four  wires)  for  the 
incoming power supply. The wire used must 
conform to local and national electrical codes 
for  the  specified  power  consumption  rating. 
See Table 1.
Wall Switch or Wall Thermostat Kits
(optional kits, see Page 17)
Low voltage wire is provided for the wall switch 
connection.  The wires gage requirements are 
shown on Table 1.
Power Supply Wire gage 
Voltage
Wire gage
Fuse
120 V
14 gA.
15 AMP
240 V
14 gA.
20 AMP
Wall Switch / Thermostat Wire gage
Voltage
Wire gage
5 VOLTS
18 gAgE
Table 1
Figure 1
LOCATINg yOUR MERIT PLUS ELECTRIC 
FIREPLACE
Your new fireplace may be installed into existing 
framing or built into a wall (see Figure 1).
When choosing a location for your new fire-
place, ensure that the general instructions are 
followed.  Also, for the best effect, install the 
fireplace out of direct sunlight and away from 
overhead lighting.  See Figure 1.
fireplace shown in gray.
TOOLS AND bUILDINg SUPPLIES
NORMALLy REqUIRED
TOOLS:
Phillips Screwdriver
7/16" Socket Drive
Hammer
Saw And/or Saber Saw
Level
Measuring Tape
Plumb Line
Electric Drill And Bits
Pliers
Square
Gloves
IMPORTANT NOTE: This fireplace system 
is not difficult to install. However, in the 
interest of safety, it is recommended that 
the  installer  be  a  qualified  or  certified 
“tradesman”  familiar  with  commonly 
accepted fireplace installation and safety 
techniques  as  well  as  prevailing  local 
codes.
bUILDINg SUPPLIES:
Framing Materials
Wall Finishing Materials
Caulking Materials 
     (noncombustible)
Top View Showing Approved 