  Changing a sequencer program using point job: 
setSeqNo 
                       
 
The sequencer number being selected can be changed using the point job. 
However, a complicated command cannot be created because the number of commands for 
sequencer program is 100 steps maximum.  Therefore, you need to create some sequencer 
programs (executed when the power is turned ON, during standby and during operation) separately 
so that you can switch between the programs using “setSeqNo.” 
For example, if you set “setSeqNo02” for “Job on Start of Cycle (Job on Run Mode)” and 
“setSeqNo01” for “Job on End of Cycle (Job on Run Mode)”, the 2nd sequencer program will be 
executed during the operation and the 1st sequencer program will be executed during standby. 
 
If you change the number while running a program, the running program or sequencer program will 
not be changed instantly.  After changing the number, the running program will be changed when 
the robot restarts from standby state. 
 
 
Command 
Category 
Command 
Parameter 
Job 
Variable, 
Comment, 
System Control 
Changes the sequencer program 
number when the robot starts running 
after Wait Start. 
Sequencer Program 
Number 
setSeqNo 
 
 
The sequencer program number can be set using variables or expressions. 
 
 
 
Features II                                               CARTESIAN Benchtop Robot 
 