Laser beta lasermike LS8000-3 Manual Do Utilizador

Página de 221
LaserSpeed 8000-3 Instruction Handbook
 
RS-232/RS-422 Communication 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 122 of 221 
Revision A (Sep 2007) 
 
Baud Rate & Framing Settings 
Setting 
Baud Rate 
Framing 
1 230.4k 7n2 
2 115.2k 7n2 
3 57.6k 7n2 
4 38.4k 7n2 
5 19.2k 7n2 
6 9600 7n2 
7 4800 7n2 
11 230.4k 8n1 
12 115.2k 8n1 
13 57.6k 8n1 
14 38.4k 8n1 
15 19.2k 8n1 
16 9600 8n1 
17 4800 8n1 
RS-232 Maximum Cable Lengths 
Beta LaserMike recommends the following cable lengths based on the chosen 
RS232 baud rate.  (These recommendations do not apply to RS-422, which is 
designed for long distances communications.) 
RS-232 Baud 
Rate 
Recommended Maximum 
Cable Length 
230400 10m 
115200 10m 
57600 20m 
38400 50m 
19200 100m 
9600 200m 
4800 200m 
 
If you experience problems at high baud rates when using RS-232 over a long 
cable, try decreasing the baud rate or switching to RS-422.  The RS-422 port 
is designed for long distances at high baud rates.  Beta LaserMike