Infortrend EONSTOR A16E-G2130-4 Manual Do Utilizador

Página de 98
Chapter 1: Introduction 
The subsystem is equipped with two (2) redundant, hot-swappable, 530W 
PSUs, which are installed into the rear section of the chassis. The PSU is 
permanently mounted into a 2U (dual-level) bracket especially designed to 
house both the PSU and a cooling module, which is mounted at the end of 
the 2U bracket.  
 NOTE: 
Hot-swapping the PSU also removes the cooling module at the lower 
slot. 
As shown in Figure 1-9, each PSU comes with a power socket and a power 
switch to turn the subsystem on and off. Two (2) embedded cooling fans 
provide sufficient airflow. A single LED indicates the PSU status. When a 
power supply failure occurs, the LED lights red. A rejection handle at the 
rear of the PSU is especially designed to help properly install or remove the 
module. 
 
A screw hole on the ejection handle helps secure the PSU to the chassis.  
 
Figure 1-9: PSU Module 
Please refer to Appendix B for the technical information of the PSUs. 
1.2.7 Cooling 
Modules 
PN: IFT-9273ECFanMod 
Two cooling modules are implemented within the rear sections of PSU 
modules. (see Figure 1-10.) The cooling fans operate at two (2) fan speed 
levels. When the subsystem operates normally, the cooling fans operate at 
the lower speed. If a major component fails or when one of the temperature 
thresholds is violated, the cooling fans automatically raise its rotation speed.  
More technical information can be found in Appendix B
Subsystem Components      
                                                
1-9