Chapter 2: Hardware Installation 
 
2.4  General Installation Procedure 
Following all the instructions provided below can save subsystem 
installation time. Detailed, illustrated instructions for each component are 
given in the following sections. 
 
 CAUTION! 
To ensure that your system is correctly installed, please follow the steps 
outlined below. If you follow these steps, installation will be fast and 
efficient. If you do not follow these steps, you may accidentally install the 
hardware incorrectly. 
 
 Step 1. 
Unpack: Unpack the subsystem and confirm that all the 
components on the Unpacking Checklist have been 
included. (See Section 2.5
 Step 2. 
Install an optional BBU: If an optional BBU has been 
separately purchased, it should be installed prior to 
operating the subsystem. (See Section 2.7
 Step 3. 
Rack/Cabinet installation: If the subsystem is going to be 
installed in a rack or cabinet, it should be installed prior to 
installing the hard drives. Installing the subsystem into a 
rack or cabinet requires at least two (2) people. (See 
Section 2.10
 Step 5. 
Install hard drives: Separately purchased SATA-II/SATA-
I hard drives must be individually installed into the drive 
trays. (See Section 2.8
 Step 6. 
Install drive trays: After the hard drives have been 
installed into the drive trays, the drive trays must be 
installed into the enclosure itself. (See Section 2.9
 Step 7. 
Cable connection: Use the power cords that came with the 
subsystem to connect the subsystem to the main power 
source. Use self-purchased RJ-45 cables (see Chapter 4 for 
more details) to connect host ports to the network or 
external devices. 
 Step 8. 
Power up: Once the components have been properly 
installed and all cables are properly connected, you can 
 
General Installation Procedure 