Chapter 3: Subsystem Monitoring 
 
 
3.3.1 Default Threshold Values 
Table 3-7 shows the default threshold values for the EonStor A16E-G2130-
4 subsystem. If any of these values are surpassed, the alarm will sound: 
 
Upper Threshold 
Lower Threshold 
+3.3V 
+3.6V +2.9V 
+5V 
+5.5V +4.5V 
+12V 
+13.2V +10.8V 
CPU Temperature 
90ºC 5ºC 
Controller Board 
Temperature 
80ºC 5ºC 
Enclosure Ambient 
Temperature 
40ºC 0ºC 
Table 3-7: Default Threshold Values 
The thresholds in Table 3-7 are default threshold values and may be 
changed. To see how to change these values, please refer to the Generic 
Operation Manual on the CD that came with your system. 
 
3.3.2 Failed Devices 
If any of the following components fails, the audible alarm will be triggered: 
•  RAID controller module 
•  Cooling fan modules 
•  PSU modules 
•  BBU module 
•  Hard disk drives 
 
 NOTE: 
When temperature exceeds a preset threshold, the controller’s charger 
circuits will stop charging. You will then receive a message that says 
“Thermal Shutdown/Enter Sleep Mode.” When the temperature falls 
back within normal range, the battery will resume charging.  
  
 
Audible Alarm 
3-9