EonStor A16E-G2130-4 Installation and Hardware Reference Manual  
D.4  Connecting the UPS to the Subsystem 
D.4.1  Connect the PSU Module Power Cords 
The two (2) power cables shipped with the subsystem must be plugged into 
the power cord sockets in the rear of the PSU modules. The plug at the other 
end of the power cable must be inserted into a socket on the UPS. (See 
Figure D-2) Please refer to the UPS manual to determine the location of 
these sockets. The UPS must then be connected to main power. 
D.4.2  Set the Baud Rate 
The default baud rate for the COM 2 serial port is 38400 and must be 
changed to 2400. For instructions on changing the baud rate, please refer to 
the  SCSI to SATA RAID Subsystem’s Operation Manual that came with 
the subsystem. 
D.4.3 Connect COM2 
The separately purchased audio-jack to DB9 serial cable connects the 
COM2 port on the controller module to the UPS directly. (See Figure D-2
The cable transmits UPS status updates to the controller module and will in 
turn determine the write policy of the controller module. To connect the 
serial communication cable to the subsystem controller, insert the audio jack 
connector on one end of the cable into the COM2 port on the controller 
module. To see how to connect the DB9 connector to the UPS, please refer 
to the documentation that came with your UPS. 
 
Figure D-2: Connecting the UPS to the Subsystem 
 
 
 
D-2  
Connecting the UPS to the Subsystem