Checking the Voltage Setting (Model 140 and Model 240 only)
ATTENTION: On some systems a label covers the power connector, which is located
at the rear of your system unit. Remove the label and then check the
voltage-selection switch to verify that it is in the correct position. If you set this
voltage switch to the wrong position, you might permanently damage your system
unit.
Check the setting of the voltage-selection switch at the rear of your system unit.
Ÿ
If the voltage range in your country is between 100 and 125 volts, check to see
that 115 is visible. (Use the 115-volt setting in the U.S. and Canada.)
Ÿ
If the voltage range in your country is between 200 and 240 volts, check to see
that 230 is visible.
Ÿ
If no voltage-selection switch is present, your system unit has an auto-ranging
power supply. The power supply automatically switches to the correct setting.
If you need to adjust the voltage setting, slide the switch to the correct position.
Note:  Voltage selection is not needed on Model 150 as it uses an autoranging
power supply.
   
Chapter  1. System Startup
1-15