IM-30/IM-100 offers 2 input ports; designated as Input Port 0 
nd Input Port 1.    Both ports are TTL level. The input ports are accessed 
 typical circuit that you can use to input a 
1.4.7 Input/Output 
Input Ports 
The MAVIS 
a
via the 10-pin circular connectors on the back of the camera. Please refer 
Table 2-1 for input port pin assignments. 
For each port, an input voltage between 0.0 and 1.5VDC indicates a logical 
0. An input voltage between 3.5 and 5.0 VDC indicates a logical 1. Typical 
current draw for the input port is 1mA.   
Figure 1-6 is an example of a
signal into the MAVIS IM-30/IM-100 cameras. 
 
Figure 1-9: Typical Input Circuit 
By default, Input Port 0 is assigned to receive an external trigger (Ex-Trig) 
signal that can be used to control the start of exposure. Also you can 
change the Ex-Trig signal to Input Port 1 and please refer “5.6 External 
Trigger” for detail information. 
Output Ports 
The MAVIS IM-30/IM-100 offers 4 output ports; designated as Output Port 0, 
Output Port 1, Output Port 2 and Output Port 3, all are TTL level. The 
output ports are accessed via the 10-pin circular connectors on the back of 
the camera. Please refer Table 2-1 for input port pin assignments. 
For each port, an output voltage between 0.0 and 0.44VDC indicates a 
logical 0. The maximum low level output voltage (i.e., 0.44VDC) will be 
present when the driver is sinking the maximum allowed input current of 
 - 
13