current settings is 5.   
Formula 1: 
Max. Frames/s = 1 / (((240 + 2) x 15.28us) + 15.28us) 
Max. Frames/s = 269.2 
Formula 2: 
  
 
Max. Frames/s = 1 / (5 x 125us) 
  
 
Max. Frames/s = 1600 
Formula 3: 
  
 
Max. Frames/s = 1 / (1000 us + 28us) 
  
 
Max. Frames/s = 972.76 
By using the calculations above, the AOI for this particular scenario can be 
calculated at 269 frames per second. 
1.4.2 Test  Pattern 
The MAVIS IM-30/IM-100 series cameras offer an internal generated test 
pattern for testing camera transmission. The test pattern will show a gray 
bar running diagonally, moving upwards at 1pixel/frame. 
 
Figure 1-2: MAVIS IM-30/IM-100 gray bar test pattern 
 
When setting camera to test pattern mode, then camera will 
keep this configuration even after rebooting the camera. Please 
be sure to disable test pattern mode after your test completed 
testing.  
 -