HP XC System Software 3.2.1 Manual Do Utilizador

Página de 158
You can access the Onboard Administrator through a graphical Web-based user interface, a
command-line interface, or the simple object access protocol (SOAP) to configure and monitor
the enclosure.
You can add a second Onboard Administrator to provide redundancy.
The Onboard Administrator requires a password. For information on setting the Onboard
Administrator Password, see
1.2.4 Insight Display
The Insight Display is a small LCD panel on the front of an enclosure that provides instant access
to important information about the enclosure such as the IP address and color-coded status.
depicts the Insight Display.
Figure 1-10 Server Blade Insight Display
You can use the Insight Display panel to make some basic enclosure settings.
1.3 Server Blade Mezzanine Cards
The mezzanine slots on each server blade provide additional I/O capability.
Mezzanine cards are PCI-Express cards that attach inside the server blade through a special
connector and have no physical I/O ports on them.
Card types include Ethernet, fibre channel, or 10 Gigabit Ethernet.
1.4 Server Blade Interconnect Modules
An interconnect module provides the physical I/O for the built-in NICs or the supplemental
mezzanine cards on the server blades. An interconnect module can be either a switch or a pass-thru
module.
A switch provides local switching and minimizes cabling. Switch models that are supported as
interconnect modules include, but are not limited to:
Nortel GbE2c Gigabit Ethernet switch
Cisco Catalyst Gigabit Ethernet switch
HP 4x DDR InfiniBand switch
Brocade SAN switch
A pass-thru module provides direct connections to the individual ports on each node and does
not provide any local switching.
Bays in the back of each enclosure correspond to specific interfaces on the server blades. Thus,
all I/O devices that correspond to a specific interconnect bay must be the same type.
Interconnect Bay Port Mapping
Connections between the server blades and the interconnect bays are hard wired. Each of the 8
interconnect bays in the back of the enclosure has a connection to each of the 16 server bays in
the front of the enclosure. The built-in NIC or mezzanine card into which the interconnect blade
connects depends on which interconnect bay it is plugged into. Because full-height blades consume
two server bays, they have twice as many connections to each of the interconnect bays.
28
Hardware and Network Overview