The Fast/Slow Transition parameter defines how far away from a target position the RC3000 will switch 
from fast to slow motor speed.  The Coast Range defines where the RC3000 will de-energize the motor 
drive to allow the mount’s inertia to coast into the target position.  The Max Error parameter defines how 
close to the target position will be considered good enough.  
Note that the DC motor control module in the RC3000 provides for smooth acceleration/deceleration, load 
regulation and dynamic braking of the motors. 
1.3.7 Polarization Control 
The RC3000 calculates the required position and automatically moves the polarization axis as part of the 
satellite LOCATE function.  The following diagram shows the polarization axis sign convention used.  The 
diagram depicts looking at the arc of satellites from behind the antenna. 
 
The RC3000 allows the user to specify the type of polarization axis mechanism present.  If a circular 
polarization scheme is present, no automatic movement of the polarization axis is performed.  If a linear 
polarization scheme is present, the RC3000 will calculate the theoretical position as a function of mount 
latitude, mount longitude and satellite longitude.