HP RC3000 Manual Do Utilizador

Página de 143
RC3000 Antenna Controller 
Chapter 2 
Installation 
 
 42  
Azimuth/Elevation/Polarization Calibration.  The next three steps calibrate the mount’s elevation, 
azimuth and polarization axes. Place the RC3000 in MANUAL mode.  Values for the azimuth, elevation 
and polarization axes should be displayed, though they may not be reasonable since calibration has not 
yet been performed. 
For each axis, limit switch status will be confirmed, position feedback will be calibrated and total range of 
movement will be tested. 
NOTE: be careful when initially moving a mount since limit switches may not yet be configured 
correctly.  In MANUAL mode, movement will stop whenever a particular jog key is released.  The 
RC3000 may also always be turned off to stop movement. 
Throughout the 3 axis’ calibration procedures, two MAINTENANCE screens will be used extensively. 
One of the MAINTENANCE screens used is the Analog to Digital Voltage screen (see 3.3.2.1).  This 
screen shows raw data coming from antenna position sensors (potentiometers and resolvers). 
 
AZ: 1.114   181.30 33004    AD VOLTAGES 
EL: 1.143 1 122.30 22264    22.3   L1:1 
POL:2.237   181.30 33044           L2:1 
SIG: 3.756(1) <1>RF <2>SS1 <3>SS2 <4>GND 
 
Another MAINTENANCE screen that will be used is the Limits Maintenance screen ( see 3.3.2.5).  This 
screen shows the current sensed state of limit switches for all three axes. 
 
AZIM CW:0  CCW:1  STOW:0 (0-OFF)  LIMITS 
ELEV UP:1   DN:1  STOW:1 (1- ON)  ACTIVE 
 POL CW:0  CCW:1  STOW:0 
<BKSP>MAKE LIMITS INACTIVE    <MODE>EXIT 
 
Before beginning axes calibration, the installer should become familiar with accessing these screens.