HP RC3000 Manual Do Utilizador

Página de 143
RC3000 Antenna Controller 
Chapter 3 
Detailed Operation 
 
 75  
 
3.2.2.2 Stow 
The STOW mode automatically moves to the mount’s predefined “stow” position.  See appendix B for the 
list of stow positions for the various mounts supported.   
Like the DEPLOY mode, STOW requires an explicit confirmation to initiate movement. 
<MODE>MENU (DO NOT STOW)            STOW 
 
<BKSP>CONTINUE STOW 
 
 
After initiation a sequence of movements will be performed to stow the antenna. The sequence of axes 
movements will be mount dependent.  As each axis moves, its label (AZIM/ELEV/POL) will flash and the 
current position will update.  The target stow positions will be displayed in parenthesis.    
AZIM:-123.4 (   0.0)                STOW 
ELEV:  55.1 ( -67.5) 
 POL: -56.7 (   0.0) 
MOVING TO (STOW)       <STOP>HALT MOTION 
 
The following describes a typical sequence of movements: 
- the azimuth axis is moved to its stow position (typically AZIM:0.0).  After moving to this indicated 
position, the RC3000 will confirm the position by looking to see if the azimuth stow switch is active.  If the 
azimuth stow switch is not recognized, the mount will be moved a short distance either side of the current 
position trying to find the azimuth stow switch.  If the controller fails to see the azimuth stow switch the 
following message will be displayed: “*CANNOT FIND AZ STOW SWITCH* <MODE>EXIT” and no 
further stow movements will be performed. 
- if stowing of the polarization axis is enabled, the polarization axis will next move to its defined stow 
position.  As with the azimuth axis, if a polarization stow switch (if the mount is so equipped) is not 
confirmed then the message “*CANNOT FIND POL STOW SWITCH* <MODE>EXIT” will be displayed 
and no further stow movements will be performed. 
- if the azimuth and optional polarization movements complete successfully then the elevation axis will 
move to its stow position.  Typically this movement ends when the elevation stow limit is encountered.  
Following completion of movement to the stow position, the RC3000 will return to MANUAL mode.  The 
automatic movement may be terminated anytime by pressing the Stop key. 
Many mounts have unique stow sequence requirements.  Check appendix B to see if your mount has any 
unique stow situations.  Stow and deploy parameters may be customized via the Stow and Deploy 
Positions configuration screen (3.3.1.3.10).  Typically the default parameters will be correct for a 
particular mount.