HP GRACO OR PRO TI1681A Manual Do Utilizador

Página de 70
Repair 
50
309293J
Fluid Adjustment Valve Repair
1.
Prepare the gun for service, page 41.
2.
Remove the fluid adjustment valve (25). It can only 
be replaced as a complete assembly. See F
3.
Screw the valve (25) into the gun handle. Torque to 
15-25 in-lb (1.7-2.8 N•m).
Fig. 32. Fluid Adjustment Valve
Air Valve Repair
1.
Prepare the gun for service, page 41.
2.
Remove the barrel, page 46.
3.
Remove the fluid adjustment valve (25) from the 
handle (17). Remove the spring (15). See F
4.
Remove the air valve (21 ) with a pliers. Inspect the 
seal (21a*) and replace if damaged. Be sure the 
seal is pressed securely onto the valve so the outer 
cone is flats.
5.
Inspect the u-cup (6*). Do not remove the u-cup 
unless damaged. If removed, install the new one 
with its lips facing into the gun handle (17).
6.
Install the air valve (21) and spring (15) into the gun 
handle (17). 
7.
Install the fluid adjustment valve (25). Torque to 
15-25 in-lb (1.7-2.8 N•m).
8.
Install the barrel, page 46.
Fig. 33. Air Valve
CAUTION
Clean all parts in non-conductive solvent compatible 
with the fluid being used, such as xylol or mineral 
spirits. Use of conductive solvents can cause the gun 
to malfunction. 
TI1684A
25
CAUTION
When removing the air valve (21) be careful not to 
damage the seat area. 
TI1685A
25
15
21
*6
17
21a*