Honeywell ADEMCO 6150RF Guia Da Instalação

Página de 8
 
- 2 -
 
WIRING TABLE 
Keypad 
Control Panel 
Wire Color 
Data In 
Green 
− 
− Aux Pwr (GND) 
Black 
+ Aux Pwr 
Red 
Data Out 
Yellow 
Note:  NO (normally Open) and C (common) are the 
connections for the relay output 
+
6150RF-003-V2
NO C
Y
G
 
Figure 2 - 6150RF Wiring Connections
 
 
APPLICATION GUIDELINES  
Use the following guidelines when planning an installation: 
•  Local wireless keys (wireless keys programmed directly into the 6150RF) may be used regardless of whether the 
RF receiver in the 6150RF is enabled or disabled. 
•  If using bi-directional devices, be sure to enable the transmitter module in the 6150RF. 
•  If transmitters are programmed into the control panel, be sure to enable the receiver. (Make sure you do not 
exceed the number of receivers supported by the control panel.) 
•  If a local wireless key is programmed to arm/disarm or to trigger a relay on the control panel, a user code must be 
entered into the 6150RF. This user code must also be programmed into the control panel. 
•  You must set the House ID only if you are using RF keypads and/or bi-directional devices; AND the House ID 
Source is the 6150RF (Local).
 
6150RF Application Guide 
The following guide outlines how to program the wireless keys, RF receiver, and the House ID in the 6150RF for your 
installation. 
*  Two 6150RFs are needed for this application: one assigned to partition 1 and one assigned to partition 2. 
**  If using an RF keypad on only one partition, the 6150RF’s partition assignment in panel programming must match the partition. 
*** If set for Local on a partition control, the 6150RF’s partition assignment must match the one programmed in the BD device.
 
Are you using 
6150RF Programming Options 
System Control Panel 
RF keys 
beyond 
system’s 
capacity? 
RF receivers 
beyond 
system’s 
capacity? 
RF keypads and/or 
Bi-directional 
devices on more 
than 1 partition? 
Program 
Wireless Keys 
Into 
Receiver 
Enable 
House ID 
Source*** 
4110DL, 4110XM, 4140XMP, 
VISTA-20HWSE 
N/A 
N/A 
N/A 
6150RF 
OFF  
Local [0] 
NO 
NO 
N/A 
System 
ON [1] 
System [1] 
YES 
NO 
N/A 
6150RF 
ON [1] 
System [1] 
VISTA-10P, VISTA-10SE, VISTA-
15, VISTA-15P, VIA-30PSE 
YES 
YES 
N/A 
6150RF 
OFF [0] 
Local [0] 
NO 
NO 
NO 
System 
ON [1] 
System [1] 
YES 
NO 
NO 
6150RF 
ON [1] 
System [1] 
YES 
YES 
NO 
6150RF 
OFF [0] 
Local [0] 
NO 
YES 
YES* 
System 
OFF [0] 
Local [0] 
VISTA-20SE, VISTA-20P 
YES 
YES 
YES* 
6150RF 
OFF [0] 
Local [0] 
NO 
NO 
NO** 
System 
ON [1] 
System [1] 
YES 
NO 
NO** 
6150RF 
ON [1] 
System [1] 
YES 
YES 
NO** 
6150RF 
OFF [0] 
Local [0] 
NO 
YES 
YES 
System 
OFF [0] 
Local [0] 
VISTA-40, VISTA-50P, VISTA-
128B, VISTA-128BP 
YES 
YES 
YES 
6150RF 
OFF [0] 
Local [0]