Hill Phoenix P074749F Manual Do Utilizador

Página de 32
COMPONENT
All measurements are taken per ARI 1200 - 2002 specifications.
E
NERGY
 D
ATA
OWZA
Defrost Controls
Model
Defrosts 
Per Day
Electric Defrost
6
Timed Off Defrost
7
Hot Gas Defrost
Reverse Air Defrost
Fail-Safe
(min)
Termination
 Temp (°F)
Fail-Safe
(min)
Termination 
Temp (°F)
Fail-Safe
(min)
Termination 
Temp (°F)
Fail-Safe
(min)
Termination 
Temp (°F)
OWZA - 8'
2
50
46
50
46
- - -
8
- - -
- - -
- - -
6  Low temperature defrost
7  Medium temperature defrost
8  "- -  -" not an option on this case model.
Guidelines & Control Settings
Model
24hr Energy
Usage
(kWh)
Suction Pressure
@ Case Outlet
(psig)
Superheat Set
Point @ bulb
(Fo)
Discharge
Air
(Fo)
Return
Air
(Fo)
Discharge
Air Velocity
5
(FPM)
OWZA - 8’ 
(med temp)
9.3
60.8
6 - 8
25.7
33.3
200
OWZA - 8’ 
(low temp)
13.5
16.3
6 - 8
-17
3
200
5 Average discharge air velocity at peak of defrost.
System Requirements
Model
Volts
Phase
Hz
Plug
Style
Cord
Length
OWZA - 8'
230
1
60
L14-30P
10'
1  For export cases, a NEMA L6-30 electrical plug is used.
Condensing Unit Data (2 units/case)
Model
Volts
Phase
Frequency
(Hz)
HP
RLA
2
(amps)
LRA
3
(amps)
Refrig.
Condenser
Fans
Lbs. of 
Refrig.
Amps
4
Watts
OWZA - 8’ 
(med temp)
208-230
1
60
3/4
7.7
37.0
R404A
1.4
70
5
OWZA - 8’ 
(low temp)
208-230
1
60
1-1/2
15.4
74.0
R404A
2.8
140
10
2  RLA = Running Load Amps
3  LRA = Locked Rotor Amps
4  Amps shown are included in RLA rating.
2