How To Set Regeneration Cycle Program
1
 
How to set the regeneration
cycle program.
The regeneration cycle program on your Iron Curtain Filter
has been factory preset, however, portions of the cycle
or program may be lengthened or shortened to suit local
conditions.
To expose cycle program wheel, grasp timer in upper left-
hand  corner  and  pull,  releasing  snap  retainer,  and  swing
timer to the right.
To  change  the  regeneration  cycle  program,  the  program
wheel must be removed. Make sure the timer is in the service
position  and  then  unplug  the  power  cord.  Grasp  program
wheel and squeeze protruding lugs toward center of wheel.
Lift  program  wheel  off  timer.  (The  arm  on  the  program
actuator switch may need to be moved to facilitate removal.)
After making the necessary adjustments described in steps
2, 3, and 4, install the program wheel on the timer. Place
program  wheel  over  the  protruding  lugs  and  gently  push
program wheel on until the tabs on the lugs are snapped in
place  over  the  wheel.  (The  arm  on  the  program  actuator
switch may need to be moved to facilitate installation.)
Return  timer  to  closed  position  engaging  snap  retainer  in
back plate. Make certain all electrical wires are located above
snap retainer post. Plug in power cord.
The program wheel as shown in the drawing is in the service
position. As you look at the numbered side of the program
wheel, the group of pins starting at 10 determines the length
of time that your Iron Curtain Filter will backwash.
For example: If there are six pins in this section, the time of
the backwash will be 12 minutes (2 minutes per pin).
To lengthen backwash time, remove 1" long roll pin(s) from
pin storage on timer (1 pin needed for each 2 minutes to be
added). Beginning at number 8 and counting back, remove
pin(s) extended out back of program wheel (1 pin for each
long roll pin to be added to extend backwash time). Replace
with long roll pin(s) so it extends out back equal distance with
existing pins. IMPORTANT: After installing long roll pin(s),
turn the manual regeneration knob clockwise one revolution
to make sure long roll pin(s) do not touch drive gear (Item 22,
Figure 7, page 13).
3
 
How to change the length of
air recharge cycle (ARC).
The  group  of  holes  between  the  last  pin  in  the  backwash
section and the second group of pins determines the length
of time that your Iron Curtain Filter is in the air recharge cycle
rinse (2 minutes per hole). Note: This cycle also uses the
set of pins on the backside of the program wheel simul-
taneously with the first set of spaces on the front side of
the program wheel.
(Refer to page 3 for factory settings)
To lengthen the air recharge time, remove 1" long roll pin(s)
from pin storage on timer (1 pin needed for each 2 minutes
to  be  added).  Beginning  at  number  10  and  counting  up,
remove  pin(s)  (1  pin  for  each  long  roll  pin  to  be  added  to
extend air recharge time). Replace with long roll pin(s) so it
extends out back equal distance with existing pins. For each
long roll pin added, move the rapid rinse pin to the higher
numbered end of wheel.
After the rapid rinse pins, leave two holes then place two pins.
IMPORTANT: After installing long roll pin(s), turn the manual
regeneration  knob  clockwise  one  revolution  to  make  sure
long roll pin(s) do not touch drive gear (Item 22, Figure 7,
page 13).
4
 
How to change the length of
rapid rinse time.
The second group of pins on the number side of the program
wheel determines the length of time that your Iron Curtain
Filter will rapid rinse (2 minutes per pin). To lengthen the rapid
rinse  time,  add  pins  at  the  higher  numbered  end  of  this
section  as  required.    After  the  rapid  rinse  pins,  leave  two
holes then place two pins.
The regeneration cycle is complete when the program actua-
tor  microswitch  drops  off  the  last  pin.  The  program  wheel
however, will continue to rotate until the homing microswitch
drops into the notch on the program wheel.
FIGURE 5
2
 
How to change the length of the
backwash time.
Pin Storage
Backwash Section
- pins 10-20
(2 min. per pin)
Air Recharge Cycle
Section - pins 22-38
(2 min. per hole)
Rapid Rinse
Section - pins 40-44
(2 min. per pin)
Cycle Advance
- pins 46-48
Cycle Shut Off
- pins 50-52
Air Pump Run Time - pins 0-8
extending out back
(2 min. per pin)
Program Wheel