PNEG-1153 CALC-U-DRI Moisture/Matic/Manager
4. INSTALLATION
4. For conditions where straw or chaff can accumulate in the restrictor funnel, the grain can
be channeled over the sensor with angled brackets in the down spout.
Figure 4N
Sensor Cut-Out for Round Down Spouts
1. When using a sensor in a down spout, there must be a CONSTANT density of grain flowing
over the sensor for accurate readings. This flow must be independent of the flow or velocity
of the grain stream. It is recommended that a restrictor be used to slow the grain speed over
the sensor such as used in Step . A modified open top version may have to be used.
of the grain stream. It is recommended that a restrictor be used to slow the grain speed over
the sensor such as used in Step . A modified open top version may have to be used.
Moisture/Matic Electrical Box and Sensor Installation Instructions
1. The Calc-U-Dri Moisture/Matic can be near the unit’s main control box, discharge auger, or
other locations that are easily accessible and of convenient height for you to observe and
use. Mount the electrical box using four (4) 5/16" x 1-1/2" bolts, lock washers and nuts.
use. Mount the electrical box using four (4) 5/16" x 1-1/2" bolts, lock washers and nuts.
2. Included with the Calc-U-Dri Moisture/Matic are 27 feet of one-half (1/2)" liquidtite conduit.
This is to be used to protect the sensor wire between the Calc-U-Dri Moisture/Matic box
and the sensor.
and the sensor.
3. A 4 x 4 junction box, sensor wire, and liquidtite is available to extend the sensor wire up to
250 feet, if required. Determine the shortest distance from the sensor to the junction box.
Use the 27 feet of one-half (1/2)" liquidtite conduit and feed the sensor wire through it using
the connector provided. There should be six (6)" of sensor wire inside the junction box. Any
excess wire or conduit may be cut off. Be sure not to cut off too much since both the conduit
and the sensor wire need to be connected at the other end to the Moisture/Matic box.
Use the 27 feet of one-half (1/2)" liquidtite conduit and feed the sensor wire through it using
the connector provided. There should be six (6)" of sensor wire inside the junction box. Any
excess wire or conduit may be cut off. Be sure not to cut off too much since both the conduit
and the sensor wire need to be connected at the other end to the Moisture/Matic box.
4. Connect the Calc-U-Dri sensor wires in the 4 x 4 junction box to the top of the terminal strip.
The leads from the Moisture/Matic box go to the bottom of the terminal block. Be careful to
match the color coded wires to each other - red to red, etc.,
match the color coded wires to each other - red to red, etc.,
Then attach
the junction box lid.