GSI Outdoors PNEG-1153 Manual Do Utilizador

Página de 46
14
PNEG-1153 CALC-U-DRI Moisture/Matic/Manager
4. INSTALLATION
4. For conditions where straw or chaff can accumulate in the restrictor funnel, the grain can 
be channeled over the sensor with angled brackets in the down spout. 
Figure 4N 
Sensor Cut-Out for Round Down Spouts
1. When using a sensor in a down spout, there must be a CONSTANT density of grain flowing 
over the sensor for accurate readings. This flow must be independent of the flow or velocity 
of the grain stream. It is recommended that a restrictor be used to slow the grain speed over 
the sensor such as used in Step . A modified open top version may have to be used.
Moisture/Matic Electrical Box and Sensor Installation Instructions
1. The Calc-U-Dri Moisture/Matic can be near the unit’s main control box, discharge auger, or 
other locations that are easily accessible and of convenient height for you to observe and 
use. Mount the electrical box using four (4) 5/16" x 1-1/2" bolts, lock washers and nuts.
2. Included with the Calc-U-Dri Moisture/Matic are 27 feet of one-half (1/2)" liquidtite conduit. 
This is to be used to protect the sensor wire between the Calc-U-Dri Moisture/Matic box 
and the sensor.
3. A 4 x 4 junction box, sensor wire, and liquidtite is available to extend the sensor wire up to 
250 feet, if required. Determine the shortest distance from the sensor to the junction box. 
Use the 27 feet of one-half (1/2)" liquidtite conduit and feed the sensor wire through it using 
the connector provided. There should be six (6)" of sensor wire inside the junction box. Any 
excess wire or conduit may be cut off. Be sure not to cut off too much since both the conduit 
and the sensor wire need to be connected at the other end to the Moisture/Matic box.
4. Connect the Calc-U-Dri sensor wires in the 4 x 4 junction box to the top of the terminal strip. 
The leads from the Moisture/Matic box go to the bottom of the terminal block. Be careful to 
match the color coded wires to each other - red to red, etc., 
 Then attach 
the junction box lid.