PNEG-1153 CALC-U-DRI Moisture/Matic/Manager
9
4. INSTALLATION
2. Position the sensor connecting band on the discharge tube so that the rectangular hole is 
toward the discharge end. Mark the outline of the rectangular hole and the edges of the 
band on the discharge auger tube. Cut a hole in the discharge tube eight (8)" long so the 
outline of the rectangular hole is removed (stay inside the total overall length marks of the 
band). Cut up one side of the discharge tube about one third (1/3) of the way around the 
tube. This extra room is for ease of removing flighting in the next step. 
3. Replace the connecting band on the discharge tube in the same position as in 
(above) and mark the flighting at each end of the rectangular hole. Weld the discharge 
auger flighting to the shaft 3/8" beyond each of the marks. After the flight is welded at these 
points, cut out six and one half (6-1/2)" of the flighting all the way to the center shaft.
4. Smooth all the rough edges from the cut area and position the sensor hole centered over 
the six and one half (6-1/2)" area, then tighten the connecting band.
5. Before installing the sensor, see Sensor Installation 
Sensor Cut-Out for Flat Bottom Discharge Units
DISCONNECT POWER TO THE AUGER MOTOR BEFORE PROCEEDING ANY FURTHER!
1. Determine where the sensor can be located. 
 There must be at least one 
full pitch of flight before and after the sensor. 
Figure 4D 
CAUTION