Everpure 2001 Manual Do Utilizador

Página de 60
SUPREMA 2001 - OPERATION & SERVICE MANUAL 
Suprema 2001 - Operation & Service 
July 6, 2001 
Page 15 of 60 
 
TOTAL COUNTER RESET 
 
This software contains a special access code that enables the service person to reset all 
the counters to zero, including the "
VEND TOTAL
" counter. This operation should be 
performed before a unit is re-installed in the field. 
 
1.  To perform a "
TOTAL COUNTER RESET
", 
 
a)  Switch the power to the coffee maker "
OFF
" (switch is at the rear of the 
unit). 
 
b)  Press the "
SET
-
UP
" mode button on the inside door panel and keep it 
depressed. 
 
c)  With "
SET
-
UP
" mode button pressed, switch power to coffee maker "
ON
". 
 
d)  The following message will now appear on the display, 
 
 
 
 
 
 
e)  Enter the "
TOTAL COUNTER RESET
" access code (described below). 
 
 
 
 
 
"TOTAL COUNTER RESET" ACCESS CODE 
 
The following is the factory preset "
TOTAL COUNTER RESET
" access code - press the 
following in the sequence outlined below; 
 
1 COFFEE 
2 MILD 
STRENGTH 
3 LARGE 
CUP 
4 MEDIUM 
CUP 
5 SMALL 
CUP 
 
 
Once the access code has been entered, a counter will appear on the top left of the 
display, and will quickly increment from 0 to 255. Once this is complete, press 
START
” for the brewer to cycle once to re-establish its home position. 
 
 
 
 
 
 
 
 
ENTER ACCESS 
       CODE:
 
!
Note:
    
When the reset is 
complete, the unit 
will automatically 
exit to the 
“standby” mode, 
and the internal 
light will remain 
ON
” temporarily.