Everpure 2001 Manual Do Utilizador

Página de 60
SUPREMA 2001 - OPERATION & SERVICE MANUAL 
Suprema 2001 - Operation & Service 
July 6, 2001 
Page 23 of 60 
 
SETTING BOTTOM PAUSE DELAY 
 
This feature allows a delay in the position of the bottom pause to obtain maximum 
vacuum and capacity in the brewer. For example, if this setting is at 0.5 seconds, the 
bottom pause will occur 0.5 seconds after the switch reads the pause position on the 
cam. The piston will stop lower in the cylinder, creating more vacuum and increasing 
the quantity of liquid that can be pulled into the cylinder. 
 
1.  To set the "
DELAY PAUSE
", press the "
UP
" button on the hidden menu 
scroll buttons and scroll until the following message appears, 
 
 
 
 
 
a)  Press the "
START
" button to enter the set mode. 
b)  Using the hidden setting adjustment buttons, increase or decrease the 
timing for the bottom pause delay. 
c)  To exit the "
SET DELAY PAUSE
" mode and proceed to the next setting, 
press the "
UP
" or "
DOWN
" scroll buttons. 
  
 
CANCELING MESSAGES (MESSAGES ON, OFF or "ACTIVE") 
 
The following is a list of all the cancelable messages in this version of software. Most 
of these messages can also be programmed to be "active", meaning they will disable the 
unit until the message has been cleared. Use this chart as a quick reference. 
 
CANCELABLE MESSAGES 
Refill Large Hopper 
Refill Small Hopper 
Refill Chocolate 
Empty Grounds 
Call Key Operator 
Service Message 
Custom Messages 
Temp. Too Low 
 
1.  To cancel one of the passive messages, or to make the message "active", 
press the "
UP
" button on the hidden menu scroll buttons until the 
following message appears, 
 
 
 
 
 
a)  Press the "
START
" button to enter the set mode. 
b)  Scroll through the messages by pressing the "
START
" button. 
c)  To cancel a message or to make it "
ACTIVE
", once it is displayed on the 
LCD press either one of the two hidden setting adjustment buttons to 
switch it to "
OFF
" or "
 ON 
-
ACTIVE
". 
d)  Press “
START
” to save the settings. 
e)  To enable a message again, repeat the above procedure and switch the 
message to "
ON
" (either passive or active). 
f)  To exit, press one of the hidden scroll buttons. 
 
DELAY PAUSE 
PRESS <START>
 
MESSAGES ON/OFF 
PRESS <START>
 
!
Note:
    
The upper half of 
the display 
indicates which 
message is to be 
canceled, and the 
lower half of the 
display indicates 
the status of the 
message (
ON
-
PASSIVE
ON
-
ACTIVE
or 
OFF
). All new 
units are factory 
set with every 
message set to 
ON
-
PASSIVE
”.
 
 
!
Note:
    
Each of the 
messages in the 
table can be 
individually set to 
ON
-
ACTIVE
”. 
Please be aware 
that if a message 
is set to “
ON
-
ACTIVE
”, the 
function 
corresponding to 
that message will 
be disabled when 
the message 
appears. Make 
sure to inform the 
caretaker of the 
proper procedure 
required to clear 
the messages.