Everpure 2001 Manual Do Utilizador

Página de 60
SUPREMA 2001 - OPERATION & SERVICE MANUAL
 
Page 34 of 60 
July 6, 2001 
Suprema 2001 - Operation & Service 
 
BREWER RINSE CYCLE 
 
1.  Add VKI approved brewer cleaner to the brew chamber and activate the 
brewer rinse cycle by pressing the "
RINSE CYCLE
" button on the control 
panel inside the front door. 
 
To cancel the rinse cycle if it was pressed accidentally, press any button 
(except the “
START
” button) on the front selection panel. This will exit the 
rinse cycle and return the unit to the “standby” mode. 
 
 
a)  Select the type of rinse cycle required. For a brewer rinse, press the 
"
COFFEE
" button on the front selection panel to begin the cycle. 
 
b)  The piston will now move to the top of the cylinder, water will pour in, 
and the brewer will pause for about 5 minutes. During this time, the 
cleaner will break down all the oils and stains that have accumulated on 
the brewer. 
 
 
To cancel the five-minute pause and proceed to the seven rinse cycles, press 
the “
START
” button. For proper brewer cleaning, it is recommended that the 
full cycle be performed. 
 
 
c)  After the 5 minutes have elapsed, the brewer will cycle, dumping the 
cleaner into the waste container in the process. The brewer will then 
automatically cycle water seven consecutive times to rinse the cleaner 
from the brewer. After the rinse cycle is completed, the brewer will stop 
and the coffee maker will automatically exit the rinse mode. 
 
 
To cancel the seven rinse cycles, press the “
START
” button. For proper 
brewer cleaning, it is recommended that the full cycle be performed. 
 
 
d)  After the rinse cycle is complete, brew a few cups of coffee to re-
lubricate the brewer. 
 
 
 
 
WARNING:
 Make sure the waste container is under the brewer spout to catch the water 
coming from the brewer (throughout the complete rinse cycle).