Everpure 2001 Manual Do Utilizador

Página de 60
SUPREMA 2001 - OPERATION & SERVICE MANUAL 
Suprema 2001 - Operation & Service 
July 6, 2001 
Page 37 of 60 
 
TRANSFERRING SETTINGS FROM ONE SUPREMA TO ANOTHER 
 
Using the VKI Data Link downloader, it is possible to for you to transfer all the 
settings from one Suprema coffee maker, to one or several other Suprema coffee 
makers. For example, if a customer requests three Suprema coffee makers with the 
exact same settings, only one needs to be set up. Once the first unit is programmed, the 
settings can be loaded into the Data Link, and then downloaded from the Data Link to 
the other two units. This will eliminate the need to repeatedly program multiple units 
with the same settings. All the settings in the "
SET
-
UP
" mode will be transferred, with 
the exception of the counters. 
 
To transfer settings from one Suprema coffee maker to another, the procedure outlined 
below must be performed. This needs to be done with the power to the coffee machine 
"
ON
". 
 
 
 
 
STEP 1 - TRANSFERRING SETTINGS TO THE DATA LINK DEVICE 
 
1.  Connect the Data Link phone jack harness to the free connector on the 
back of the front board. 
 
2.  Press the "
SET
-
UP
" button on the back of the front board. 
 
a)  The following message will appear on the display, 
 
 
 
 
 
3.  Press the bottom scroll button to the right of the "
START
" button. 
 
a)    The following message will appear on the display, 
 
 
 
 
 
 
4.  Press the "
START
" button on the Suprema front selection panel. 
 
a)  The settings in the Suprema "
SET
-
UP
" will now be transferred to the 
Data Link device. 
 
 
 
 
COPY DATA LINK 
TO SET-UP
 
COPY SET-UP TO 
DATA LINK
 
!
Note:
    
Although the 
identical settings 
will be transferred 
from a pre-
programmed unit 
to a non-
programmed unit, 
some fine-tuning 
may be required 
for product and 
water settings. 
This is due to 
slight differences 
with the 
tolerances of 
certain 
components, such 
as valves, motors 
and ingredient 
dispensers.