Everpure 2001 Manual Do Utilizador

Página de 60
SUPREMA 2001 - OPERATION & SERVICE MANUAL
 
Page 40 of 60 
July 6, 2001 
Suprema 2001 - Operation & Service 
 
MESSAGE 
  POSSIBLE CAUSE 
CORRECTIVE ACTION 
ENTER SET-UP             
SET TEMPERATURE 
 
The rear board is set for a mechanical 
thermostat, but the machine is 
equipped with an electronic 
temperature probe. 
 
(
  Go to the “
SET TEMPERATURE
” menu and 
set the electronic temperature probe. 
INCOMPATIBLE 
SOFTWARE LEVEL 
 
The software version (EPROM) in the 
Data Link downloader in not compatible 
with this equipment and will be 
downloaded. 
 
(
  Replace the software version (EPROM) 
with one that is compatible with the 
Suprema model. The words “
SUPREMA
” 
will be printed on the EPROM decal. 
PLEASE CALL FOR 
ROUTINE SERVICE
 
 
 
This message is a reminder that regular 
maintenance may be due and will not 
stop the operation of the coffee maker. 
 
(
  The coffee maker is due for routine 
maintenance. 
(
  To reset the message, enter the 
"
SET
-
UP
"
 
and reset the service counter. 
 
PLEASE CHECK   
BREWER HARNESS
 
 
 
The brewer harness is not connected to 
the rear board. 
(
  Connect the brewer harness to the rear 
board. 
PLEASE CHECK 
OVERFLOW HARNESS
 
 
 
Overflow harness is not connected to 
the rear board. 
(
  Connect the overflow harness to the rear 
board. 
PLEASE CHECK         
TANK HARNESS
 
 
 
The water tank harness is not 
connected to the rear board. 
(
  Connect the water tank harness to the 
rear board. 
PLEASE CHECK      
WATER SOURCE
 
 
 
Indicates a problem with the main water 
supply not getting to the water tank. 
(
  At this point, the water tank is not full 
and this message has to be reset. To 
reset it, switch the power off and on. 
(
  If the problem persists, check all 
components on the water line (water 
filter, tubing, fittings, etc.).  
(
  Check inlet valve to make certain it is 
functioning properly.  
(
  In the case of a temporary disruption 
with the water supply, the coffee maker 
will reset itself after every hour. 
 
PRESS PRODUCT          
TO RESET MESSAGE
 
 
 
The "
OPEN BREWER
" button has been 
pressed.  
(
  Pressed the "
OPEN BREWER
" button once 
more to close the brewer and exit. 
(
  At this point, pressing the appropriate 
buttons on the front selection panel will 
reset the product counters. 
 
PROBES                  
CALL FOR SERVICE
 
 
 
The main level probes are covered with 
lime/calcium. 
 
(
  The water tank may require deliming. 
(
  The main level probes need to be 
cleaned/delimed. 
 
SELECTION                
NOT AVAILABLE
 
 
 
Product selected may be disabled. 
(
  Check the "
ENABLE SWITCHES
" menu to 
see if product has been canceled. 
(
  Check the price of the selection to make 
certain it has not been disabled (set 
below zero).