Operating the Equipment Locally
 
Step Action  
Result 
Scroll to Menu 3.1.7 and edit 
the video test pattern to be 
displayed. Press Save.  
Edits the video test pattern to be displayed. 
Scroll to Menu 3.1.10 and edit 
the parameter for framesync 
enable (ENABLED or 
DISABLED). Press Save.  
Edits the parameter for framesync enable. 
Scroll to Menu 3.1.10.1 and 
edit the PAL framesync offset 
range (-199999 to +199999 
pixels) and the NTSC 
framesync offset range (-
199999 to +199999 pixels). 
Press Save.  
Edits the PAL framesync offset range and the 
NTSC framesync offset range. 
Scroll to Menu 3.1.14 and 
Menu 3.1.15 edit the 
embedded audio group 
(NONE, ONE, TWO, THREE 
or FOUR). Press Save
Edits the embedded audio data IDs and audio 
channel. 
3.7.3 
Setting Down Conversion Mode 
This menu allows the user to set the receiver to produce a down converted SD 
version of the incoming HD video source. 
Note:  The RX1290 provides ‘grade 2’ down conversion video quality. The 
suitability of grade 2 video for broadcast will depend on the intended 
application. 
 
Table 3.12  Setting Down Conversion 
Step Action 
Result 
Scroll to Menu 3.1.8 and edit 
the parameter for down 
conversion enable 
(ANAMORPHIC, CROPPED, 
LETTERBOX or DISABLED). 
Press Save.  
Edits the parameter for down conversion enable 
and the output format. 
3.7.4 
Setting SD Monitor Aspect Ratio 
This menu allows the user to set the SD output aspect ratio. 
Note:  This function only applies to 4:2:0 video, and has no effect on the down 
converted SD output 
  
EN/LZT 790 0003/2 R1A
 
 
 
 
3-15