Enviro 50-645 Manual Do Utilizador

Página de 42
5
4
3
2
1
0' (0m)
0' (
0m
)
1' (
0.3
1m
)
4' (
1.2
2m
)
4' (1.22m)
8' (
2.4
5m
)
10' (3.06m)
20' (6.11m)
30' (9.17m)
Ve
nt 
R
es
tric
t o
r C
on
fig
ura
tio
n
Figure 30. Possible Vent Configurations
Figure 31. Possible Vent Configurations
Initial Installation
QUALIFIED INSTALLERS ONLY
v
ent
 c
onFiguRations
 
anD
 R
estRictoR
 s
ettings
:
Figures 30 shows the range of venting options, 
it  shows  possible  vent  configurations  if  the 
unit is top vented, for vertical and horizontal 
terminations, any layout that remains within 
the  shaded  area  is  acceptable.  Having  the 
fewest  number  of  elbows  is  ideal,  as  they 
tend  to  disrupt  air  movement.  Using  45˚ 
elbows  is  preferable  to  using  90˚  elbows. 
Also,  a  shorter  vent  system  will  perform 
better than a longer one.
The  vent  restrictor  controls  the  amount  of 
air  moving  through  the  vent  pipe.  Longer 
vertical  vent  lengths  necessitate  greater 
restriction; position 1 is open and position 5 
is maximum restriction. Figure 30 shows the 
vent  restrictor  settings  required,  relative  to 
the  length  of  vent  pipe.  The  vent  restrictor 
is located on the right side of the fireplace, 
above  the  glass.  Figure  31  shows  the  vent 
restrictor handle and the holes that indicate 
the different levels. To avoid injury, it is best 
to make this adjustment when the fireplace is 
cool or use welder’s gloves or oven mitts.
Note: 0,0 in Figure 30 represents a 90˚ bend 
directly off the outlet of the unit, 38¾ inches 
(985mm) for hard pipe and 41¼” (1048cm) 
for  flex  pipe  from  floor,  in  all  horizontal 
instances.
23
NOTE:  The  total  length  of  the  vent 
pipes  can  not  exceed  30  feet  (9.17  m). 
Any combination of rise and run can be 
used as long as it lays within the shaded 
area (a total of three (3) 90° elbows or 
six  (6)  45°  elbows  can  be  used).  In 
addition to what is shown, if a 90° 
elbow  is  used  in  the  horizontal 
plane, 3 feet (91.4 cm) must be 
subtracted from the allowable 
horizontal  run  (for  each 
45°  elbow,  1½  feet  must 
be  subtracted  from  the 
allowable  horizontal 
run).