ELECTRICAL 
The ENVIROGAS EG 22.Z/CLEARANCE .DV. will operate with no external power supply. These models have a 
Millivolt gas control which uses the pilot flame to generate enough electricity to operate the main burner. 
 
The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence 
of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR 
ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA. 
 
•  Operation of the fan increases the efficiency and the heat output of the appliance. 
 
WARNING:
 ELECTRICAL GROUNDING INSTRUCTIONS. 
For your protection against electrical shock, this unit should be properly grounded. 
 
INSTALLING OR REMOVING THE BLOWER 
The blower does not require lubrication. 
1. Turn the unit off and make sure the unit is cool before you start to install the fan assembly. 
 
2. Open the bottom louver assembly to access gas control compartment. 
 
3. Place the blower assembly already installed on the fan-mounting bracket, in the center, rear of the appliance. Place blower 
over the two screws provided on the base of the appliance. 
 
4. Install the electrical box on either the left side of the appliance. This electrical box will have the fan controller already 
installed on the box. 
 
5. Wire the blower and fan controller to the wiring diagram supplied on this page. (Page 19) 
 
6. This unit must be hard wired to household wiring and should be properly fixed to the appliance with a stain relief connector. 
 
INSTALLING REMOTE THERMOSTAT OR WALL SWITCH  
RECOMMENDED WIRE SIZE 
for thermostat installation: 18 gauge, 2 wire solid core, Low Voltage wire. (Bell wire) 
 
1. 
Install the 18 Gauge wire supplied to the two terminals on the thermostat or remote wall switch. 
 
2. 
Connect the other end of the wire to the gas valve using the two outside terminals on the front of the gas valve. 
Use the terminals marked (TP/TH and TH) as shown below. 
 
RECOMMENDED MAXIMUM LEAD LENGTH 
(TWO WIRE) WHEN USING WALL 
THERMOSTAT 
WIRE SIZE MAXIMUM 
LENGTH 
14 GAUGE 
100 FEET 
16 GAUGE 
64 FEET 
18 GAUGE 
40 FEET 
20 GAUGE 
18 FEET 
CAUTION 
Label all wires prior 
to disconnection 
when servicing 
controls. Wiring 
errors can cause 
improper and 
dangerous 
operation. Verify 
proper operation 
after servicing. 
 
19