WLC/WLH sPECIFICAtIons 
notE:
 Due to ongoing development programs, design and specifications may change without notice.
WLC/WLH sYstEM oPtIons
dIsCHArgE AIr sPEEd And FLoW @ 230V
Model
High CFM
Low CFM
Coil
FPM
throw/Ft.
9/12
400
350
Dry
900
15
18/24
750
675
Dry
1,225
25
30/36
1,170
900
Dry
1,250
27
S1C/S1H
WLC/WLH
WLC/WLH oBsErVEd sound VALuEs
(230V High speed Fan)
Model
dBA
09/12
45
18/24
56
30/36
60
WLC/WLH IntErConnECtIng-LInE sIzE 
system Capacity 
Btuh
Liquid 
o.d.
suction 
o.d.
Condensate 
I.d.
09
1/4”
1/2”
1/2”
12
1/4”
1/2”
1/2”
18
3/8”
5/8” *
1/2”
24
3/8”
3/4”
1/2”
30
3/8”
3/4” **
1/2”
36
3/8”
3/4” **
1/2”
 * 
WLC/WLH Suction Connection size is 3/4” O.D. and must  bush down at the 
WLC/WLH Unit.
 
**
 WLC/WLH Suction Connection size is 5/8” O.D. a factory supplied kit is provided 
to transition to 3/4” O.D. interconnect.
WLC/WLH ELECtrICAL sPECIFICAtIons
MODEL #
VOLTS/HZ/PH
FAN
RLA
HP
HEATER
K.W.
AMPS
TOTAL
AMPS
MIN
VOLT
M.C.A.
HACR
BRKR
sMALL CABInEt  09/12
09/12
115/60/1
0.64
0.02
0.64
104
0.8
15
115/60/1
0.64
0.02
0.75
6.50
7.14
104
8.9
15
208/230/60/1
0.34
0.02
0.34
197
0.4
15
208/230/60/1
0.34
0.02
3.00
13.04
13.38
197
16.7
20
MEdIuM CABInEt 18/24
24
115/60/1
1.20
0.083
1.20
104
1.5
15
115/60/1
1.20
0.083
0.75
6.52
7.72
104
9.7
15
115/60/1
1.20
0.083
1.25
10.90
12.10
104
15.1
20
208/230/60/1
0.56
0.070
0.56
197
0.7
15
208/230/60/1
0.56
0.070
3.00
13.04
13.60
197
17.0
20
208/230/60/1
0.56
0.070
5.00
21.74
22.30
197
27.9
30
LArgE CABInEt 30/36
30/36
208/230/60/1
0.80
1/10
0.80
197
1.0
15
208/230/60/1
0.80
1/10
5.00
21.74
22.54
197
28.2
30
CooLIng sYstEMs WItH WALL unIts 
Condenser              
Wall unit
 Btuh 
sEEr  sHr
EEr 
ref.
S1C9
WLH09
9,000
13.0
.79
11.8
R22
S1C2
WLH12
12,000
13.0
.74
12.9        
R22
S1C8
WLH24
18,000
14.0
.78
13.0
R22
S1C4
WLH24
 24,000
13.0 
.70
12.5 
R22
S1C3
WLC36
30,000
13.0
 .72  12.6
R22
S1C6
WLC36
 33,600 
13.0
 .69
12.1     
R22
*
 Important - This system has been designed and manufactured to meet 
ENERGY STAR criteria for energy efficiency. However, proper refriger-
ant charge and proper air flow are critical to achieve rated capacity and 
efficiency.  Installation  of  this  prod-
uct  should  follow  the  manufacturer’s 
refrigerant  charging  and  air  flow  in-
structions.  Failure  to 
confirm  proper  charge 
and airflow may reduce 
energy  efficiency  and 
shorten equipment life.
HEAt PuMPs sYstEM oPtIons WItH WALL unIts
Condenser  Wall unit 
Cooling Btuh  Heating Btuh
sEEr  HsPF
sHr
EEr
CoP
ref.
S1H9
WLH09
9,000 
8,600
13.0
8.0
 .75
11.6
3.6 
R22
S1H2
WLH12
11,400
10,600
13.0
8.0
.73
11.5
3.4 
R22
S1H8
WLH24
18,000
16,400
13.0
7.7
.73
12.1
3.8
R22
S1H4
WLH24
23,000
20,600
13.0
8.3
.71
11.9
3.5
R22
*