Cyclades Marine Instruments 2.3.0 Manual Do Utilizador

Página de 160
4: Configuring the Web Interface
AlterPath Console Server User Manual
37
 
 
If you require port authentication, then you must add users through 
Wizard Step 3: Access.
 
To configure other authentication methods (e.g., LDAP, RADIUS, 
TACACS), select the Expert button to switch to Expert Mode and 
select:  Security > Authentication
3. Select Apply Changes to save configuration to Flash. 
4. Select the Next button or proceed to the next section, Step 3: Access.
Field Name
Definition
Connection Protocol
The method you will use to access the serial ports. 
Cyclades recommend SSH to ensure that all data and 
authentication information are encrypted. Other 
options are Telnet and Raw Data (for un-negotiated 
plain socket connections). 
Flow Control
The method of flow control used by the attached 
devices (Hardware, Software, or None).
Baud Rate
The serial speed on each console port, which should 
match the equipment you will connect to. The 
recommended Baud Rate is 9600.
Data Size
Number of data bits used by the attached devices (5, 
6, 7 or 8).
Parity
Parity used by the attached devices (None, Odd, or 
Even). 
Stop Bits
Number of stop bits used by the attached devices.
Authentication Req’d
Selecting this checkbox sets the system to require 
authentication to access the ports. This is done in the 
local database in the ACS.