CALL TOLL FREE 1-800-DR-OWNER         7
 
 
Hydraulic Safety  
 
 
ESCAPING PRESSURIZED FLUID FROM HYDRAULIC SYSTEM LEAKS CAN HAVE ENOUGH FORCE TO 
PENETRATE SKIN AND CAUSE SERIOUS INJURY OR DEATH.  HYDRAULIC FLUID CAN REMAIN 
PRESSURIZED WHILE THE MOTOR IS OFF DUE TO THE RETURN SPRING FORCE ON THE RAM.  ALWAYS 
FOLLOW THESE PRECAUTIONS:
 
• 
NEVER USE YOUR HAND OR ANY PART OF YOUR BODY TO CHECK FOR HYDRAULIC SYSTEM LEAKS 
WHILE THE SYSTEM IS PRESSURIZED. 
• 
NEVER REMOVE THE FILL/DIPSTICK CAP FROM THE HYDRAULIC FLUID PORT WHILE THE MOTOR IS 
RUNNING OR WHILE THE TANK IS STILL WARM AFTER THE MOTOR IS SHUT OFF.  HOT PRESSURIZED 
FLUID CAN CAUSE SERIOUS INJURY, SO WAIT FOR THE HYDRAULIC TANK TO COOL BEFORE 
REMOVING CAP. 
• 
THE WOOD SPLITTER MUST BE ON A LEVEL SURFACE. 
• 
ALWAYS RELEASE RESIDUAL ENERGY FROM PRESSURIZED HYDRAULIC FLUID AND ALLOW THE FLUID 
TO COOL BEFORE DOING ANY MAINTENANCE OR REPAIR WORK ON THE WOOD SPLITTER. 
• 
PLEASE FOLLOW THESE STEPS TO DEPRESSURIZE THE SYSTEM AND RELEASE RESIDUAL HYDRAULIC 
ENERGY BEFORE STARTING ANY REPAIRS. 
UNPLUG THE WOOD SPLITTER FROM THE POWER SOURCE. 
MOVE THE OPERATING HANDLE DOWN AND UP FROM ONE LIMIT OF TRAVEL TO THE OTHER AT 
LEAST FOUR TIMES AND HOLDING THE HANDLE FOR THREE SECONDS AT EACH LIMIT OF 
TRAVEL. THE RAM SHOULD NOT MOVE DURING THE 4TH CYCLE AND SHOULD BE FULLY 
RETRACTED. 
CALL 1(800) DR-OWNER (376-9637), OR A QUALIFIED HYDRAULIC MECHANIC, FOR ASSISTANCE TO 
REPLACE WORN COMPONENTS. 
• 
PERIODICALLY CHECK FOR HYDRAULIC FLUID LEAKS BY PLACING A SHEET OF CARDBOARD UNDER 
THE WOOD SPLITTER WHILE THE SYSTEM IS RUNNING. 
• 
GET PROFESSIONAL MEDICAL HELP AT ONCE IF HYDRAULIC OIL PENETRATES ANYONE'S SKIN. 
• 
NEVER MAKE ANY ADJUSTMENTS TO THE HYDRAULIC SYSTEM. 
 
 
Tip:  Reference page 23 for Troubleshooting Tips.