Furuno SC-60 Manual Do Utilizador
APPENDIX A
A-4
Schematic diagrams
HDG IN port (listener)
Load requirements
Isolation: Optocoupler
Input Impedance: 220 ohm
Max. voltage: ±15V
Isolation: Optocoupler
Input Impedance: 220 ohm
Max. voltage: ±15V
HDG OUT1 port
Output drive capability
Max. 10 mA