Fujitsu MAN3367 Manual Do Utilizador

Página de 302
C141-E124-01EN
4 - 57
4.2.8.2 Accounting date (Page 0E, Code 0002)
                             Bit
Byte
7
6
5
4
3
2
1
0
4
5
(MSB)
X'0002' (Parameter code)
(Accounting Date)
(LSB)
DU
DS
TSD
ETC
TMC
LBIN
LP
6
0
0
0
0
0
0
0
1
7
X'06' (Parameter Length)
8
(MSB)
9
10
Accounting date Year (4 ASCII characters)
11
(LSB)
12
13
(MSB)
Accounting date week (2 ASCII characters)
(LSB)
The Accounting date specified by parameter code 0002h is a parameter that may be savable using a
LOG SELECT command to indicate when the device was placed in service.  If the parameter is not
yet set or is not settable, the default value placed in the parameter field shall be 6 ASCII blank
characters (20h).  The field shall not be checked for validity by the device server.
4.2.8.3 Specified cycle count over device lifetime (Page 0E, Code 0003)
                             Bit
Byte
7
6
5
4
3
2
1
0
4
5
(MSB)
X'0003' (Parameter code)
(Specified Cycle Count Over Device Lifetime)
(LSB)
DU
DS
TSD
ETC
TMC
LBIN
LP
6
0
1
0
0
0
0
1
1
7
X'04' (Parameter Length)
8
(MSB)
9
10
Specified Cycle Count Over Device Lifetime (4-byte binary number)
11
(LSB)
The Specified cycle count over device lifetime is a parameter provided by the device sever.  The
specified cycle count over device lifetime parameter shall not be savable by the application client
using the LOG SELECT command.  The parameter value is a 4-byte binary number.  The value
indicates how operation or reliability outside the limits specified by the manufacture of the device.