Fujitsu D1522 Manual Do Utilizador

Página de 44
Error messages
30 - English
A26361-D1522-Z120-3-6319
Missing or invalid NVRAM token
Switch the device off and on again. If the message is still displayed, please contact your sales
outlet or customer service centre.
Monitor type does not match CMOS - RUN SETUP
Correct the entry for the monitor type in the 
Main
 menu of the 
BIOS Setup
.
On Board PCI VGA not configured for Bus Master
In the 
BIOS Setup
, in the 
Advanced
 menu, submenu 
PCI Configuration
, set the 
Shared PCI Master
Assignment
 entry to 
VGA
.
One or more RDRAM devices are not used
One or more RDRAM devices have bad architecture/timing
One or more RDRAM devices are disabled
Contact your system administrator or contact our customer service centre.
Operating system not found
Check the entries for the hard disk drive and the floppy disk drive in the 
Main
 menu and the
entries for 
Boot Sequence
 submenu of the 
BIOS Setup
.
Parity Check 1
Parity Check 2
Switch the device off and on again. If the message is still displayed, please contact your sales
outlet or customer service centre.
Previous boot incomplete - Default configuration used
By pressing function key 
[F2]
 you can check and correct the settings in 
BIOS Setup
. By
pressing function key 
[F1]
 the system starts with incomplete system configuration. If the
message is still displayed, please contact your sales outlet or customer service centre.
Real time clock error
Call the 
BIOS Setup
 and enter the correct time in the 
Main
 menu. If the message is still
displayed, please contact your sales outlet or customer service centre.
Service Processor not properly installed
The server management controller has not been correctly installed. If the message is still
displayed, please contact your sales outlet or customer service centre.
Storage Extension Group = xy
Configuration error, x Storage Extensions(s) found, configured are y
SE(s).
Device List: k1, k2 ...
The specified number of storage expansion units (SEs) in the 
BIOS Setup
 menu 
Server - Storage
Extensions - Number of connected SE
 is incorrect. Check how many SEs within the group are
connected at the server and change the setting in 
BIOS Setup
. Check whether you have
assigned the same device ID twice.
xy = Group number
x = Number of SEs found on the communication bus
y = Number of SEs entered in 
Number of connected SE
k1, k2 ... = Device ID of the storage extensions found