Esoteric D-07 Manual Do Utilizador

Página de 16
14
Messages
“- - -” appears on the right side of the display.
  An incompatible signal is input.
  Do not input signals other than PCM.
  Check digital device connections.
XLR, RCA, RCA2 or OPT flashes.
  The unit cannot detect a digital signal. Press the INPUT button to 
select a terminal to which a digital device is connected.
  Turn  on  the  connected  device.  Confirm  the  settings  of  the 
connected device.
NO WORD!
  No word clock signal is being input. (See page 10 for details.)
WRD ERROR!
  The frequency of the input source does not match word frequency.
  Select 44.1, 88.2 or 176.4 kHz during Super Audio CD playback.
  Set the “MCK” (Master clock) setting to “PLL1” or “PLL2” when you do 
not use the word sync mode.
  An incompatible signal is input. Check the word sync connections 
and the setup of the connected devices.
WRD LCKING
  Indicates that the input word clock signal is being locked. 
WRD UNLCK!
  Indicates  that  the  device  cannot  lock  to  the  input WORD  clock 
signal.  Confirm  the  frequency  setting  of  the  connected  clock 
generator.
Troubleshooting
If you experience any problem with this unit, please take the time to 
look through this chart and see if you can solve the problem yourself 
before calling your dealer.
No power.
e Make sure to plug the power cord into the AC outlet. Make sure 
there is power to the AC outlet by plugging another item such as 
a lamp or fan to test the outlet circuit.
e Press the POWER button to turn on the unit.
No sound
e Check amplifier and digital device connections.
e Check the analog audio output setting (page 11). 
Input indicator flashes.
e Turn on the device connected to the selected input terminal.
e Check whether the connection to the selected input terminal is 
correct.
A beeping noise occurs at regular intervals.
e The D-07 is in Word sync mode, but the connected device is not. 
Check the connection to the Word sync terminal and the setup of 
the connected device. 
  This phenomenon occurs when the error detected is below the 
limit of detection for the D-07 word error that would normally 
produce a WRD ERROR.
The WORD indicator flashes.
e Set the “MCK” (Master clock) setting to “PLL1” or “PLL2” when you 
do not use the word sync mode.
e An incompatible signal is input. Check the word sync connections 
and the setup of the connected devices.
If normal operation cannot be obtained, unplug the power cord 
from the outlet and plug it again. This resets the internal micro-
computer  which  can  be  disturbed  during  electrical  storms, 
power interruptions, et cetera.
Beware of condensation
When the unit is moved from a cold to a warm place, or used after 
a sudden temperature change, there is a danger of condensation; 
vapor  in  the  air  could  condense  on  the  internal  mechanism, 
making  correct  operation  impossible. To  prevent  this,  or  if  this 
occurs, leave the unit turned on for one or two hours. Then the unit 
will stabilize at the temperature of its surroundings.
Maintenance
If  the  surface  of  the  unit  gets  dirty,  wipe  with  a  soft  cloth  or 
use  diluted  neutral  cleaning  liquid.  Be  sure  to  remove  any  fluid 
completely. Do not use thinner, benzine (naphtha) or alcohol as 
they may damage the surface of the unit. For the sake of safety, 
disconnect the power plug before cleaning.