Chromalox PQ404-6 Manual Do Utilizador

Página de 12
(Supersedes PQ404-5)
PQ404-6
CHS
161-048642-001
OCTOBER, 1983
4
and
Installation, Operation
RENEWAL PARTS IDENTIFICATION
Horizontal Electric Steam Boiler
Model Number CHS 0 – 150 PSI
© 2010 Chromalox, Inc.
Power CC
Size of
Output
Nominal
90˚C
Amps
Standard Lbs. per
Model
B.H.P.
Fuse Delta
Size
Wire
per
Elements
Control
Hr. at
Number
Rating kW Contactors Size
kW
(Amps)
(M.C.M) Circuit
(kW)
System
212˚F
CHS-150*
15.3
150
5
50A 60A
30
1
300
4/0
181
2
60
452
1
30
CHS-180*
18.4
180
6
50A 60A
30
1
300
250
217
3
30
543
CHS-210*
21.4
210
7
50A 60A
30
1
600
600
253
3
60
633
1
30
CHS-240*
24.5
240
8
50A 60A
30
1
600
400
290
4
60
723
CHS-270*
27.6
270
9
50A 60A
30
1
600
600
326
4
60
814
1
30
CHS-300*
30.6
300
10
50A 60A
30
1
600
600
362
5
60
904
CHS-360
36.7
360
12
50A 60A
30
2
300
250
217
2
90
1085
3
60
CHS-420
42.9
420
14
50A 60A
30
2
600
350
254
4
90
1266
1
60
CHS-495
50.5
495
11
60A 100A
45
2
600
500
297
3
135
1492
1
90
CHS-540
55.1
540
12
60A 100A
45
2
600
600
324
4
135
1628
CHS-630
64.3
630
14
60A 100A
45
2
600
700
378
4
135
1889
1
90
CHS-720
73.5
720
16
60A 100A
45
3
600
400
324
5
135
2170
1
45
CHS-810
82.7
810
18
60A 100A
45
3
600
600
324
6
135
2441
CHS-945
96.4
945
21
60A 100A
45
3
600
700
378
7
135
2848
CHS-1080 110.0 1080
24
60A 100A
45
4
600
500
324
8
135
3255
CHS-1215 124.0 1215
27
60A 100A
45
4
600
700
378
9
135
3662
CHS-1350 138.0 1350
30
60A 100A
45
5
600
600
324
10
135
4069
CHS-1485 152.0 1485
3
60A 100A
45
5
600
700
378
11
135
4476
CHS-1620 165.0 1620
36
60A 100A
45
6
600
600
324
12
135
4883
Specifications — 480 Volt Boilers*
INSTALLATION
CAUTION: To avoid electrical shock hazard, boilers
must be suitably grounded to earth.
NOTE: Chromalox boilers are pre-tested before shipment; no internal
piping or wiring is necessary. WARNING: Substitution of compo-
nents or modification of wiring without prior consent of Chromalox,
Inc. voids warranty.
1. Locate unit on level floor or platform. NOTE: A minimum dis-
tance of 60 inches from wall, other equipment, etc. must be
allowed for removal of the elements.
2. Complete all piping to boiler. Connect water line to tagged fitting
on the motor and pump assembly, if used, or to tagged fitting on
water control feeder.
3. When any type of feed other than a pump feed is used – the exist-
ing water supply must be 10 pounds greater than the boiler operat-
ing pressure to assure water supply maintains proper water level in
boiler. Otherwise, lack of water can cause heater failure. Keep feed
water line valves open at all times.
4. All water feed systems are connected to supplied water inlet check
valve.
5. Connect steam line (with Globe valve) to boiler steam outlet. Valve
should be placed as close as possible to boiler outlet.
6. To insure maximum efficiency of supplied kw, all piping from out-
let should be insulated.
7. Drain and relief valve piping should be in accordance with state
and local codes.
CHS-360 Steam Boiler
*150 kW Thru 300 kW Boilers available in 280V and 240V. Check Factory
Boiler Serial No . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Circuit Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Model No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. of Power Circuits . . . . . . . . . . . . . . . Amps. . . . . . . . . . . . . . . . . . . . 
Electrical Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Circuit Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
National Board No . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Total Amps . . . . . . . . . . . . . . . Phase . . . . . . . . . . . . Cy . . . . . . . . . . . . . 
IMPORTANT – This data file contains the National Board Registration Certificate approving your generator. It must be kept near the generator at all times.
2 P’TROLS
3
P’TROLS
SEQUENCER