Overview
This section contains installation procedures for connection to the telephone system.
You should first follow the General Instructions and then refer to the Specific
Instructions for the type of telephone switch to be connected (loop or ground start
trunk port, station port, or page port). Refer to Section 3 for connections to the
paging system.
Required Tools
You will need the following tools for installation:
standard flat-blade screwdriver; Phillips-head screwdriver; 
wire cutters/stripper/crimper; and punch-down tool for Type 66 Block.
Select Location and
The UPAM may be mounted on a wall or backboard. It can be located either in
Physical Installation
close proximity to the telephone equipment (a modular cord is included and can be
used to connect the unit to the telephone system’s page port) or near the paging
equipment. To install the unit using the keyhole slots, install two screws (not
included) with a 7-1/2" center, letting the screw heads protrude 1/4" from the wall.
Position the unit on the screws through the slots, then tighten the screws. A 110V
AC outlet should be located nearby when using the UPAM with trunk port and page
port equipment.
Punch Block Connections
All wiring to the punch block must be 26AWG to conform to National Electric
Code ANSI/NFPA No. 70-1987.
Grounding
The UPAM is designed with protection devices which are intended to shunt to
ground any excess (surge) voltage appearing on the Tip and Ring input pair. The
metal case of the UPAM must be grounded to a ground shorting bar, if available, or
to a suitable electrical (earth) ground. Connect a ground wire to the fork-terminal
(included between the case and the screw on the lower corner of the module). An
external-tooth lockwasher ensures a good connection between the case and the
ground terminal. To conform with National Electric Code ANSI/NFPA No. 70-
1987, use 14AWG or larger wire with green/yellow insulation.