Atlas GUARDIAN PRO MLGS180B Manual Do Utilizador

Página de 4
-2-
598-1096-01
Swing the sensor head towards the clamp
screw.
For eave mount only:
Controls
INSTALLATION
W
IRE
 
THE
 L
IGHT
 C
ONTROL
.
Turn power off at the fuse or circuit breaker.
Remove the existing light fixture, if present.
These instructions show the sensor wired to flood-
lamps. The white sensor wire is neutral.  The
black sensor wire is hot.  The red wire is the
switched "hot" wire. The lighting load (Up to 500
Watts, 4.2A Maximum) is placed across the white
and red wires.
After screwing the sensor into the wall plate,
connect the junction box wires to the Light
Control wires by twisting together and securing
with wire connectors.
M
OUNT
 
THE
 L
IGHT
.
Follow the instructions that came with your light
fixture for mounting and adjusting the light fixture.
Keep regular PAR-38 lamps at least 1" (25 mm)
from the sensor. Halogen lamps should be kept
at least 2" (51 mm) from the sensor.
Black to Black
White to White
Red Sensor Wire to
Black Lamp Wire
Optional: Connect additional load across
the white and red wires. Total lighting
load including lampheads on fixture must
not exceed 500 Watts (4.2A).
Junction
Box
Lamp Holders
For under eave installation, the sensor head
must be rotated
 as shown in the next two steps for
proper operation and to avoid the risk of electrical
shock.
Rotate the sensor head clockwise 180
°
 so the
controls face down.
Clamp Screw
Controls
Controls
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the
ball joint. Tighten the clamp screw when done.