ArtDio IPC 1000 Series Manual Do Utilizador

Página de 67
 
ARTDio IPP 1000 Series
 
 
   
46
6-3  Advanced 
6-3.1  General 
 
 
 
 
Section Item 
Field  Description 
Default 
Flash Button 
Flash Time 
Set the flash time duration in seconds. Select an 
entry from the ‘Flash Time’ field drop-down box. 
200 msec 
Duration 
Sets the DTMF duration. Select an entry from the 
‘Duration’ field drop-down box. 
100 msec 
Touch Tone 
(DTMF) 
Inter-digit Time 
Select an entry from ‘Inter-digit time’ drop down 
box. 
100 msec 
Guard Time 
Line 
Sets minimum time between in-coming calls. 
Select an entry from the ‘Line’ field drop-down 
box. 
0.8 sec 
Max. Fax Rate 
The system will accommodate 2400 / 4800 / 7200 
/ 9600 / 12000 / 14400 bps. 
Select an entry from the ‘Max. Fax Rate’ field 
drop-down box. 
14400 bps 
Low Speed 
Redundancy 
Set the number of redundant packets in low speed. 
No Redundant Packets 
1 Redundant Packets 
2 Redundant Packets 
3 Redundant Packets 
4 Redundant Packets 
5 Redundant Packets 
3 Redundant Packets 
T.38 Fax Relay 
High Speed 
Redundancy 
Set the number of redundant packets in high 
speed. 
No Redundant Packets 
1 Redundant Packet 
2 Redundant Packets 
1 Redundant Packet