6-4
5708009-C
Advanced Energy
®
7. Is the Power Limit LED lit?
– If no, your unit is operating properly and delivering the requested power level.
– If you are still experiencing any issues with the questions you have just gone 
TROUBLESHOOTING PROCEDURES
The following section describes the procedures involved in troubleshooting. Use this 
section to help you identify what the LEDs described are. If you are looking for a 
more in depth troubleshooting details, see “Troubleshooting Questions” on page 6-3.
AC On LED not Lit
When the AC On LED is not lit, see Electrical Specifications on page 3-5. There also 
may be an external line fault. Check input voltage and circuit breaker specifications in 
“Electrical Specifications” on page 3-5. After correcting, send an RF Off command to 
reset the unit. If this does not work see “Troubleshooting Questions” on page 6-3.
Alarm LED Lit
When Alarm LED is lit, this means a error has been detected. This is be caused by a 
fault which creates an error code (Table 6-1. on page 6-7). Call AE Global Support if 
you have any questions regarding this.
Overtemp LED on Solid
When the Overtemp LED is on solid, the internal cold plate temperature has exceeded 
the allowable limit. When LED is solid, the output is disabled. The Overtemp and 
Alarm LEDs latch on until the cold plate temperature falls below the warning 
temperature level. 
To avoid this condition, make sure the unit is receiving proper cooling as outlined in 
the Coolant Specifications section. See “Cooling Specifications” on page 3-10.
Overtemp LED is Flashing
When flashing, this indicator shows that the internal cold plate temperature is 
approaching the shutdown limit. This state does not affect RF output.
Take precautions by ensuring that the unit receiving proper cooling as outlined in the 
Coolant Specifications Section. See Table 3-5. on page 3-10.