COMMAND SET FOR THE RS-232, AE BUS HOST PORT
Table 4-6 lists the command set for the RS-232, AE Bus Host port.
51
Duty cycle out of range
52
Minimum on/off time violated (on/off 
time must be 
≥ 10 µs).
99
Command not implemented
Table 4-5. CSR Codes for RS-232, AE Bus Host
Table 4-6. Host Port Commands for RS-232 with AE Bus 
Command
Description
Number of 
Host Data 
Bytes
Number of 
Response 
Data Bytes
1
RF off
Requests RF output off; request is always 
honored regardless of which interface has 
control. (Readback command is 162.) 
0
1
2
RF on
Requests RF output on; host control must 
have been selected.
0
1
3
regulation 
select
Sets the method of output regulation (forward 
power (6), load (7), and ext. (8)). (Readback 
command is 164.)
1 data byte
8-bit value
1
4
fwd pwr 
limit
Specifies maximum forward power that can 
be delivered; accepts a value of 0 to 8000 W 
(for the 8 kW option) or 0 to 10000 W (for 
the 10 kW option). (Readback command is 
169.)
2 data bytes
16-bit value
1
5
refl pwr 
limit
Specifies maximum reflected power that can 
be tolerated; accepts a value of 0 to 2000 W. 
(Readback command is 170.)
2 data bytes
16-bit value
1
6
ext 
feedback 
limit
Specifies the maximum external feedback 
level; accepts a value from 0 to the maximum 
external feedback value. (Readback 
command is 171.)
Note: This command sets the value at which 
the setpoint is limited during external 
regulation 
2 data bytes
16-bit value
1