Agilent Technologies Whiteboard Accessories E6385A Manual Do Utilizador

Página de 138
Installation
Navigating the Test Software
Chapter 2
25
Insta
lla
tion
Navigating the Test Software
After the Test Software has loaded, the Lucent AMPS Tests Main Menu screen will 
appear on the Test Set display (see 
). 
Configuration operations, test utilities, and tests are grouped into sub-menus. Turn and 
press the knob to access the desired sub-menu.
Figure 2-3
Lucent AMPS Tests Main Menu Screen
Main Menu Functions
Test Configuration
 – Define test information used by all tests; such as identifying 
the timing reference signal source, measurement port selection, number of averages, 
Walsh code power units, cable losses, and Base Station TX Test Port coupling factor.
Base Station Configuration
 – Enter the specific cell site and Base Station 
information that the Test Software requires to control the Base Station when 
communicating with the MSC during tests (after configuring the PC and verifying its 
operation).
Calibration/Utilities 
– Access procedures used to ensure optimal calibration of 
the Test Set and test cables.
Test Selections
 – Access the available tests.
Serial Port Configuration
 – Access routines used to define the serial port 
communication settings for interfacing with the PC serial port.