4 –Pump 38-Station Controllers
Chapter 4:  Operation
24 of 44
The following table explains the status represented by each color at the “Station Status”
screen.
Color
Label
Description
Gray outline
Offline
Station is not enabled. The controller ignores any demands or
alarms.
Green
Full
Station is enabled and idle (full).
Yellow
Demand
Station requires material.
Blue
Convey
Station is being loaded with material.
Light blue
Dry Air
Convey
Air to convey material is coming from dry air source, rather than
ambient air.
Purple
Unload
Station is dumping material into its receiver.
Blue, blinking
Priority
Station is in priority convey mode. Its pump will be temporarily
dedicated to filling it as soon as possible.
Red
Alarm
Station is in alarm.
Red outline
Critical
Station is in critical alarm. The controller has disabled the station
until the alarm is cleared.
White
Purge
Air is being drawn through material lines.
Additional basic information about each station (convey time, dump delay, and pump
assignment) is available at the “Station Operator” screen. See page 28 for details.
Detailed configuration settings for each station are available at the “Station Setup” screen.
See page 36 for details about each of these settings.