4 –Pump 38-Station Controllers
Chapter 4:  Operation
34 of 44
Filter cleaning
Our pumps have two options available for filter cleaning;  these are vacuum pulse or
compressed air filter cleaning. Touching the ENABLE/DISABLE button located in the
lower left hand corner of the pump setup screen will allow the operator to turn on/off these
two options or disable the filter cleaning option altogether.
Note: 
Each type of filter cleaning requires optional equipment that must be purchased and
installed prior to enabling this option.
4-3 Alarms
Reviewing Alarms
To review your system’s alarms, touch Alarms on any screen. The “Alarm Log” screen
appears, with the newest alarm listed first.
Figure 16:  Alarm Log Screen
To scroll up and down through the list, touch DOWN or UP at the top of the screen.
Silencing Alarms
Whenever a new alarm occurs, your controller sounds the horn and turns on the strobe light at
each central alarm.
Touch SILENCE on the alarm message banner that appears when a new alarm occurs.
The horns and lights at the central alarms turn off. Your controller has separate, configurable
settings for how long the horns should remain silent and how long the light should remain off.
If the alarm condition still exists when either of these times elapses, the corresponding device
(horn or light) turn on again and the alarm message banner appears. If a new alarm occurs,
both horns and lights turn on.  See page 39 for a list of alarms and their possible causes.