TECHNICAL DATA
Guide values for mains connection
The power cable must be dimensioned by a qualifi ed person in accordance with national and local regulations. The 
mains socket to which the machine is connected must be dimensioned for the same amperage as the machine’s 
electrical socket and extension cable, e.g. a 63 A electrical socket must be preceded by a 63 A fuse.
Nominal
voltage from 
power source
Min.
voltage
at machine
Cable area
Starting 
current
Motor output
Setting 
thermal over-
load relay
Max. cable 
length during 
operation
V
V
mm
2
A
kW
A
m
400
380
6
90*
50 Hz
22,0
44
163
400
380
10
90*
22,0
44
272
400
380
16
90*
22,0
44
435
460
440
6
90*
60 Hz
25,3
44
163
460
440
10
90*
25,3
44
272
460
440
16
90*
25,3
44
435
* Two phases soft start. The directly related phase can be loaded up to 30% more.
The hydraulic system’s pressure
Type of pressure
Pressure, Bar
Pump pressure
The pressure in the pipes between pump and main stop 
valve. The pressure varies between pressure at rest and 
max. pressure depending on which hydraulic functions 
are being used.
Tool, max*
250
Rotating function
170
Outrigger down/up
250/200
Arm functions
200
Pressure cut-off
Functions equipped with pressure cut-off can never be 
run at a higher pressure than that indicated. The follow-
ing functions are equipped with pressure cut-off for the 
respective pressure level.
Telescopic arm
180
(External hand tool - option)
(140)
Pressure at rest
The pressure that the pump delivers when no function is 
activated and the pump around valves is shut.
20 ±1
50