Denso BHT-6000 Manual Do Utilizador
86
3.2.2 Communications Parameters
In System Mode and user programs written in BHT-BASIC 3.0, you may set the
communications parameters listed below.
communications parameters listed below.
Transmission Speed
2400, 9600, 19200, 38400,
57600, or 115200 bps
57600, or 115200 bps
300*, 600*, 1200, 2400, 4800,
9600, 19200, or 38400 bps
9600, 19200, or 38400 bps
Optical interface
Direct-connect interface
Communications Port
Character Length
8 bits
7 or 8 bits
Vertical Parity
None
Odd, even, or none
Stop Bit Length
1 bit
1 or 2 bits
* The 300 bps and 600 bps are not available in System Mode.
In System Mode
Refer to Chapter 2, Subsection 2.5.3, "Detailed Description of the Functions in System
Mode," [ 4.6 ] Setting the communications environments.
Mode," [ 4.6 ] Setting the communications environments.
In BHT-BASIC 3.0
To set the transmission speed, character length, vertical parity, and stop bit length (To
set the transmission speed only for the optical interface), use the
set the transmission speed only for the optical interface), use the
OPEN
"COM:"
statement in BHT-BASIC 3.0.
OPEN
"COM:
...
"
Opens the interface port selected in System Mode.
OPEN
"COM1:
...
"
Opens the optical interface port for data transmission
routing through the CU-6000, irrespective of the setting
in System Mode.
routing through the CU-6000, irrespective of the setting
in System Mode.
OPEN
"COM2:
...
"
Opens the direct-connect interface port for data trans-
mission, irrespective of the setting in System Mode.
mission, irrespective of the setting in System Mode.
Note that it is impossible to open both the optical interface port and the direct-connect
interface port concurrently.
interface port concurrently.
Through the interface port opened by the
OPEN
"COM:"
statement, the
XFILE
statement transmits a designated file.