Denso BHT-6000 Manual Do Utilizador

Página de 178
106
S
O
H
E
T
X
C
R
C
S
T
X
E
T
X
C
R
C
S
T
X
E
T
X
C
R
C
D
L
E
D
L
E
D
L
E
D
L
E
D
L
E
D
L
E
I
D
I
D
I
D
(2 bytes)
(5 bytes)
[ 3 ] Basic Format of Transmission Messages
Basically, the BHT-6000 transmits data as units of a file.  First, it transmits a heading
text which includes the attribute information of a file (e.g., file name and the number of
data texts) to be transmitted.  Following the heading text, it transmits the data text in
the file.  A heading text and data text comprise a text.
In actual text transmission, the text is divided into several blocks, then a header,
terminator, serial number, receiver station’s ID, and CRC-16 (Cyclic Redundancy Check)
are added to each block.  This procedure forms a transmission block.  A set of
transmission blocks makes up one transmission message.
Shown below is an example of a transmission message formed with the BHT-Ir
protocol.
In the above figure, DLE SOH, DLE STX and DLE ETX are text control characters as
described in [ 2 ] Control Characters.  An ID denotes the ID number of the receiver
station, expressed by two bytes.  A serial number is expressed by a five-digit decimal
number, starting from 00001 to 32767, and identifies data texts.  For the CRC-16, refer
to [ 6 ] CRC.
You can use the control characters for expressing IDs serial numbers, or text data.
For DLEs, type DLE DLE per DLE.
Data text 1
Data text 2
Data text n
Heading
text
Transmission
Message
Data text 1
Transmission
block
Transmission
block
Text
Heading text
TIP
Serial
number
Data text 2
Serial
number
Transmission
block